5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Local Reviews
for lilburn, ga

Rated 5.0 out of 5 stars based on 5 customer reviews

Great service

Provided great service and excellent detail summary of the status of the two units.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Vu is an excellent employee and great representative...

Outstanding service for several years.. highly recommended...

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Comfort Control Maintenance

Always excellent work and very personable. Explains everything so I understand and is on time.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Ty was personable, clear in what needed to be done and worked with efficiency

We would recommend you and Ta to anyone who needed temperature control. Love those calls to let us know the time!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great job - I would highly recommend

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for lilburn, ga

Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Vu T.

Vu T. Job Checkin

Furnace repair call. Check and find air pressure sensor fail. Replace pressure sensor and furnace operating at this time.


Vu T.

Vu T. Job Checkin

Renewed 2 Comfort Club Membership plans and completed 2 heating preventative maintenance checks. Checked the safety and operations. Found the upstairs furnace 25-years-old operating at this time but in poor condition due to its age and worn parts. The system was dirty and had a badly rusted heat exchanger. Found the downstairs 16-year-old Trane heating system operating with a worn motor and a dirty blower assembly. The flue pipe was not up to code. Both systems' water safety was not up to code.


Vu T.

Vu T. Job Checkin

Renew 2 Comfort Club membership plans and complete 2 heating preventative maintenance check and repairs. Change both filters, check safety and operations. Complete 2 combustion calibration for both furnaces improve temperature and efficiency. Both furnace operating with in manufacturer spec. Need to keep checking the upstairs weak flame sensor and minor worn ignition.


Vu T.

Vu T. Job Checkin

2 furnace repair and preventative maintenance check complete. Find main system operating normally with manufacturer spec. Find upstairs furnace under-fire and producing high co level at 98ppm on high stage. Complete combustion calibration to help improve temperature, efficiency and reduce Co level 30 ppm. Replace worn flame sensor and replace worn ignition. System operating at this time. Change all filter.


Vu T.

Vu T. Job Checkin

Renew 2 Comfort Club Memberships and complete 2 furnace repair and preventative maintenance check. Find upstairs 2-year-old heating system operating within manufacturer spec. The system may have a problem with tstat, customer wants to keep an eye on Tstat. Did not change filter. Find downstairs furnace 7 years old operating with aworn ignition, worn flame sensor, and system under-fire. Suggest doing combustion calibration, change out the ignition and replace flame sensor. The customer wants to wait. System operating at this time. Replace filter.


Vu T.

Vu T. Job Checkin

Renew and complete heating pm check. Find heating system operating with in manufacturer spec. Did not change filter. Check safety and operations. System operating at this time.


Vu T.

Vu T. Job Checkin

Complete 1 system furnace repair and preventative maintenance. Replace 2 Lennox air clearer kit customer provided. Find furnace operating with manufacturer spec. System operating at this time.


Vu T.

Vu T. Job Checkin

1 furnace repair and preventative maintenance check. Replace worn flame sensor and complete combustion calibration. Change filter, check safety and operations. System operating with in manufacturer spec.


Vu T.

Vu T. Job Checkin

Complete heating pm check. Did not change filter. Find system operating within manufacturer spec. Filter 20x25x5


Vu T.

Vu T. Job Checkin

Complete 2 heating preventative maintenance check. Changed the filter. Checked the safety and operations. Found the upstairs furnace operating normally. Found the downstairs furnace operating with a worn flame sensor, worn ignition, and a weak blower capacitor but still operating at this time. Found no water protection. The gas line was not up to code and the flue pipe was not up to code.


Vu T.

Vu T. Job Checkin

No heat. Found a high pressure switch tubing clogged. Cleared the tube and the system is operating at this time. Checked and found the system operating with a weak flame sensor and a high CO level at 50ppm. Suggested repair and suggested CCI plan.


Tom K.

Tom K. Job Checkin

Furnace needs to be replaced


Vu T.

Vu T. Job Checkin

Completed 1 system furnace repair and preventative maintenance check . Change filter, check safety and operations. Find heating system operating with worn and noisy inducer motor but still operating st this time. Overall furnace operating normally.


Vu T.

Vu T. Job Checkin

Completed 2 system furnace repair and preventative maintenance check. Change filter, check safety and operations. Find both heating furnace operating normal at this time. Help install upstairs return vent for customer. Suggest apco air purifier for system in crawlspace to help improve air quality and prevent molding.