Jon was on time today which is always very important. He took his time to review his findings and walk me through the next steps. I signed up for the maintenance agreement which applied to today’s visit. The only issue is I can’t seem to get a receipt.
New guy for me but he was nice and he did his work and was very professional
The Comfort Control Technician was knowledgeable and thorough performing the service on our heating system. We were pleased with the services rendered.
I am so impressed with Comfort Control!! John was here to fix my system within hours and I was not charged the typical “weekend” or “after hours” rate. The service was very affordable!! I am so thankful for you!!!
Vu is the most knowledgeable HVAC technician, he was thorough and precise with checking every part of our systems and showing us detailed photographs so we could see and understand what was going on. ***** 5 star recommendation for Vu and Comfort Control!
Vu is an excellent technician. He performed an in depth diagnosis on the heating and air systems and performed the necessary maintenance and repairs. He has maintained our system for many years and we have always received great service.
First of all, Very friendly and informative. Answered questions and was informative as well on overall heating and air.
Really appreciate the honesty of the technicians at Comfort. No charge on a simple fix. Thanks for coming out and taking care of us.
Upon arrival i found the 1/3 HP blower motor had failed, replaced 1/3 hp motor. System is cooling at this time. System has good pressures. Outdoor systems are clean. Indoor systems are clean. Motor failed due to weak capacitor. Please send invoice to Gkimberly57@gmail.com and to kyledaniel1125@gmail.com
A/c diagnostic in loganville. System is cooling at this time. Condensate pump was really dirty. Clean condensate pump. Blower wheel is clean, evaporator coil is clean. Filter is clean.
No cool in Loganville. Upstairs zone not receiving air. Diagnosed sticking 10†Honeywell automatic damper. Need to order part and return to replace. System is operating at this time other than bonus room zone. Customer will pay when we return.
No cool loganville. Completed diagnostic found thermostat just needs to be reset. Turned system on everything came on and started cooling properly.
No cool in Loganville Ga. one system. Found ac condenser not coming on. Checked all electrical and mechanical components. Might have a consultant out later for new system.
Repair loganville. Completed replacement of evap coil. Tested for leaks found none. Pulled vacuum to 500 microns. Re charged system. System cooling at this time.
No cool loganville. Completed diagnostic. Found system very low on refrigerant. Leaking out of evap coil. System only 7 years old. Everything else clean and working in range of manufacturing spec. Ordered new coil will return next week to replace. Filled system with 410a refrigerant to get them by until I return.
Arrived on site, changed filters and cleared drain lines, checked electrical connections, amp draw, capacitance, cleaned outdoor coil and checked refrigerant pressures. Found corrosion on main level evaporator coil, will need to keep an eye on pressures going forward for potential leaks. Recommend installing surge protection to both indoor units to protect electrical systems. Both systems are operating normally at this time
One system cooling maintenance in Loganville. Arrived on site, checked filter and cleared drain line. Checked electrical connections, amp draw and capacitance, cleaned outdoor unit and checked refrigerant pressures, system is operating normally at this time, recommend installing secondary water safty switch and surge protection to both pieces of equipment. No issues present at this time
Ac maintenance in loganville. Tested operation of 2 systems. Discovered downstairs system with failed blower motor, organic growth in system which is a high respiratory irritant, dirty blower wheel, no drain line water safety, weak compressor starter, pitted main electrical switch and missing line set insulation. Discovered upstairs system with pitted main electrical switch, no drain line water safety, missing line set insulation, dirty blower wheel, system low on charge. Performed leak search and detected leak at indoor coil. Systems are 18 years old and replacement is HIGHLY recommended.
close job on hold; Vu has performed service since this date
Heating tune up loganville. Completed tune up on 2 5 year old systems. Blower wheels dirty. Coils clean. Flame sensor on upstairs system cracked. Replaced sensor. Heating and cooling properly. No secondary water safety switches. Changed filters. Signed up on maintenance plan. Cleaned outdoor units. Cleared drain lines.
Hvac tune up in Loganville, Georgia. Two systems. Changed filters. Found upstairs system not coming on due to high voltage wiring going into furnace burnt. Both nest thermostats did not have common wire hooked up. Hooked up both common wires to both thermostats and control boards and repaired high voltage wiring going into upstairs furnace. Tested mechanical and electrical components. Found downstairs ignitor to be worn. Found downstairs flame sensor to be bad and intermittently failing. Found downstairs blower wheel to be dirty. Found no water safety on either system. Found evaporator coils to be rusty, corroded and likely to leak refrigerant. Found upstairs ignitor to be worn. Found upstairs blower capacitor to be extremely weak, reading a measurement of 2 microfarads when it is rated for 10, could fail at any time. Found downstairs disconnect box for condenser to be broken with melted plug. Downstairs Ac is not functioning due to this. Found downstairs main electrical switch with ba
Two system tune up in Loganville. Arrived on site, checked filters and cleared barometric ports, checked ignition systems, electrical connections, amp draw and capacitance. Found older unit that services the left side of house has no aux drain pan and no water safty. Recommended installing wet switch to sense any moisture in the event the unit were to fail. Recommend replacing equipment in near future due to age as well as condition of equipment. The newer system that services the right side of house is functioning on a weak blower motor capacitor. I also recommend installing a secondary water safty switch to protect the electrical systems as well as serve as a backup for the pan switch. Static pressure in both units is fantastic except across the filters, recommend installing electro-static filter to help with air flow as well as helping to better clean air as it enters the system. Also, I recommend installing surge protection to both of the indoor units to protect electrical systems.
No heat in Loganville. Check and find downstairs gas furnace not operating and lock out on safety. Find pressure not operating properly. Replace e pressure sensor and system operating at this time. Check and find flame sensor weak, ignition worn and blower capacitor bad. Find system have not water protection, flue pipe not code. Customer need consultation visit for downstairs 15 year old system. Long-term customer, waive service fee.