5322 Palmero Ct
Buford, GA 30518
770-203-1600

Local Reviews
for oakwood, ga


Job Locations
for oakwood, ga

dylanwages@gmail.com

dylanwages@gmail.com Job Checkin

I found the Mainfloor with a bad condenser motor. I'm taking the motor now and will figure out if the unit is under warranty or not in the morning. If the unit has part's warranty then the cost to replace will be $350. The upstairs unit is working within normal parameters with no obvious signs of concern. 16x20x1 upstairs and 25x25x1 Mainfloor. The units have visible molding the is destructive towards overall health.


dylanwages@gmail.com

dylanwages@gmail.com Job Checkin

I found the Mainfloor with a bad condenser motor. I'm taking the motor now and will figure out if the unit is under warranty or not in the morning. If the unit has part's warranty then the cost to replace will be $350. The upstairs unit is working within normal parameters with no obvious signs of concern. 16x20x1 upstairs and 25x25x1 Mainfloor. The units have visible molding the is destructive towards overall health.


Ta K.

Ta K. Job Checkin

1 system prepaid pm. Replaced dirty filter, checked electrical and safety switches all ok at this time. Found worn ignition and weak flame safety sensor, replaced both parts and system heating at this time. Close off supply grille above the thermostat to prevent short cycle of system. Need to block off vent. Overall sustemnis heating normal at this time.


seth@comfortcontrolinc.com

seth@comfortcontrolinc.com Job Checkin

Performed 2 system heating maintenance. Found large amounts of black mold growth in upstairs supply plenum. Recommend u/v lighting system to kill mold and bacteria. No filter rack doors, so there is a larger opening to pull in attic air. No surge protection on furnace to stop electrical damage. Main level system flu pipe is single wall and will not pass code until upgraded to double wall. Basement has no form of surge protection. Recommend surge protector and double wall flu installed. Both systems operating normal at this time.


seth@comfortcontrolinc.com

seth@comfortcontrolinc.com Job Checkin

Performed 2 system heating maintenance. Installed surge protector on main level system to prevent electric damage.both systems operating normal at this time.


Phillip S.

Phillip S. Job Checkin

Found unit low on refrigerant complete job HJ2-B Quick fix and recharge Add internal sealers 90 day warranty Repair residential system and system is cooling normal at this time! Recommend maintenance program.