Jon F.

Jon F. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Found pump not working replaced customer provided the pump. Signed up for Comfort Club maintenance. The system is cooling.


David D.

David D. Job Checkin

Performed 1 ac pm, cycled system , checked DT, blower components, found wheel very dirty , cleaned wheel, changed filter, checked ac components, operating pressures and superheat, cleaned condenser coil using cleaner. System is working ok.


Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Vu T.

Vu T. Job Checkin

Complete cooling preventative maintenance check. Change the 14x20x1 filter, check operations and charge. Find system operating within manufacturer spec. Not a concern at this time.


Vu T.

Vu T. Job Checkin

Sign up 1 Comfort Club Membership plan and complete cooling preventative maintenance check. Find 4 years old Lennox system operating with in manufacturer spec. Check safety and operations. Find system molded at supply air distribution. Give customer options to remove moles and clean air.


Vu T.

Vu T. Job Checkin

Renew Comfort Club Membership and complete 1 system a/c repair and preventative maintenance check. Discovered no secondary water safety or compressor saver. Recommend adding both. System cooling at this time.


Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Vu T.

Vu T. Job Checkin

Furnace repair downstairs. The gas company shut off the system due to a claim that the vent pipe was not up to code. Checked the manufacturer specs and the system is up to code on the rubber vent connector. Turned on the system and replaced both filters for the customer. Suggest the Comfort Club Membership plan.


Ta K.

Ta K. Job Checkin

Came to inspect both system equipment. System will have to be replace for main floor system do to phaseout of equipment and not coded.Will have manager come out to evaluate system replacement.


Vu T.

Vu T. Job Checkin

Completed one system furnace repair and preventative maintenance check. Check safety and operations. Change filter Aprilaire 810. Replace flame sensor, complete combustion calibration and reduce CO level to 25 ppm and improve efficiency to 81.7%. Pull and clean blower assembly. Suggest duct cleaning and suggest apco air purifier to improve air quality and help prevent molding. System operating at this time.


Vu T.

Vu T. Job Checkin

Completed one system furnace repair and preventative maintenance check. Find two 4-year-old Lennox cooling system operating at this time. Did not change a filter, check safety and operations. Suggest installing a hard start kit for a cooling system. Suggest inline line water protection for both the evaporator coil drain line in the attic. Suggest apco air purifier to improve air quality and prevent molding.


Vu T.

Vu T. Job Checkin

Furnace repair. Found a burnt gas valve. Replaced the gas valve and the furnace operating. Tested and the system is operating well at this time.


Vu T.

Vu T. Job Checkin

1 system furnace repair and preventative maintenance check. Check and find heating system 21 year old Rheem system operating but very dirty, duct system not up to code and dirty, missing filter. Blower assembly dirty. Gas line not up to code. Find ac unit cage in, missing valve cap. Due to low load and low temperature, was not able to check proper charge but ac unit operating at this time. Suggest duct cleaning, suggest to pull/clean blower assembly, suggest to pull/clean evaporator coil in the attic, suggest to replace flame sensor, suggest to do combustion calibration for the heating system and suggest to upgrade the gas line.


Vu T.

Vu T. Job Checkin

Completed furnace repair and preventative maintenance. Find Goodman furnace operating normal at this time. Check safety and operations. Change filter.


Vu T.

Vu T. Job Checkin

Signed up 1 Comfort Club Membership Plan and completed the cooling preventative maintenance check. Changed the filter, checked the condensation pump and cleaned the AC coil. Installed a start kit and replaced the condenser capacitor. The system was overcharged with R22. The cooling system is operating normally at this time. Needs to schedule for November to come back and check on the heating system.