5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Local Reviews
for suwanee, ga

Rated 4.9 out of 5 stars based on 156 customer reviews

Great service

Good people

  • Overall Experience
  • Quality
  • Communication
  • Convenience

friendly and efficient

good service

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Good Service

Good service but a little bit of language barrier.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Service, professional, great company.

Ta is the best. We appreciate his work and the company.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Estimate

Very thorough and informative

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great job

  • Overall Experience
  • Quality
  • Communication
  • Convenience

RELIABLE SERVICE

Thorough and reliable service by Vu as always.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great review of our system and needs

Excellent presentation and character

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Job Locations
for suwanee, ga

Vu T.

Vu T. Job Checkin

Complete service call on upstairs system and not cooling properly. Check and find 15 year old system operating with low charge, burnt damage capacitor and wire to contactor, Faulty starter kit and fan motor overheating and loosing oil. Fan blade not balance. Due to system age and worn parts. Suggest to upgrade system and not repair. Find main system operating within manufacturer spec. Suggest to install hard start kit to improve start up and reduce load for Lennox system. Find basement system operating within manufacturer spec. Suggest 3 CCI plan to help keep system clean and maintain system. Customer need estimate for upstairs system. Suggest duct cleaning for both upstairs and main system.


Reece W.

Reece W. Job Checkin

Master bedroom zone was stuck. Adjusted zone damper. Cycled damper on and off and problem did not represent itself. System is cooling at this time.


Vu T.

Vu T. Job Checkin

No cool upstairs. Check and find system operating normal within manufacturer spec. Customer said system intermittently will not operate. Check did not see problems at this time. Replace Aprilaire 8448 under full warranty. If fall again may need to replace furnace control board. System operating at this time.


Jordan R.

Jordan R. Job Checkin

0906 code. No cool tripping breaker. Found bad compressor. Leslie chose to replace whole outdoor unit. Need to order and install. House empty but we have code and can install whenever. Paid in full


Reece W.

Reece W. Job Checkin

2 system ac pm check complete. Changed filters. Tested mechanical and electrical components. Found main level system with weak blower capacitor. Found upstairs condenser with weak capacitor. Recommend repairs. Chemically washed condenser coils. Replaced upstairs capacitor and main level main electrical switch. Systems are cooling at this time.


Jordan R.

Jordan R. Job Checkin

No cool upstairs. Compressor starter exploded and took out secondary controller and main electrical switch with it. Replaced all and renewed membership. System operation normal at this time. Please call and schedule maintenance


Vu T.

Vu T. Job Checkin

Find tstat was set on HOLD. Adjust setting. System operating at this time.


Reece W.

Reece W. Job Checkin

2 system ac pm check complete. Changed downstairs filter. Left replacement for upstairs. Tested mechanical and electrical components. Both systems running rough with high amps. Main level main electrical switch is burnt. Due to age and condition of systems, recommend upgrading systems to something more reliable and efficient. Systems are cooling at this time.


Jordan R.

Jordan R. Job Checkin

Found blown fuse in system. Changed fuse system came on.


Michael A.

Michael A. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Jon F.

Jon F. Job Checkin

Complete 2 system a/c repair and preventative maintenance check. found upstairs system good cleared drain line closed up open drain portion evap coil that could have possibly caused avoidable water damage. The filter is good, left a new one for the system. The downstairs blower wheel is dirty and needs to be cleaned to avoid causing extra stress to the motor and possibly have it fail prematurely. The upstairs condenser has good pressures but failing capacitor. Needs to be replaced and have compressor saver installed to keep compressor alive as long as possible. The downstairs compressor has new and good electrical components but is very low on refrigerant. Needs to be filled with a leak seal to possibly patch leak in copper lines. Both systems need secondary water safety device and surge protector for extra protection and to avoid unnecessary damage to systems. Also, recommend breathe easy packages to clean and purify the air for better comfort in the home.


Reece W.

Reece W. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. No airflow to the sunroom. Quoted mini split system. Installers will return to install mini split system for sunroom and blow in insulation in area. . Collected deposit. 19 seer heatpump mini split system. Will need an electrician to run high voltage wire.


Jordan R.

Jordan R. Job Checkin

Found worm stuck in burnt main electrical switch. Replaced switch and added hard start for compressor. System operation normal at this time


Jordan R.

Jordan R. Job Checkin

Warranty. Need to send installers back out to fix job. All pictures in ServiceTitan. Return plenum with filter cabinet has completely fallen off furnace. Need to reattach with screws re-tape and re- mastic seal. All ducts need to be taken off, collars sealed, dampers installed on supply side, flex duct black inner liner attached then outer jacket attached. Drain line needs to be re-done to so the pipe goes straight into fitting and not at severe stress bend and use pvc glue on all fitting as there was none used on install. Txv bulb needs to be completely insulated. After all repairs are made, the air balancing needs to be performed. While onsite check wiring as the light in far room has not worked since install


Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.