Fantastic service

John does a great job and is always thorough and explains the results.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Outstanding service

Very thorough presentation, very personable. Took the time to answer any and all of our questions.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great job!

Reese provided very professional and courteous service. Thanks!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

yearly maintenance- air and heat

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great late night service

I came down to my basement to find water pouring out of my system. Reese from Comfort Control was there in about an hour and had the problem quickly resolved. He was courteous and efficient. We greatly appreciated the after hours service that allowed us to sleep in a cool house without worrying about water damage.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Reece was very professional and very helpful!

I had a great experience and Reece did a great job tried everything to check out my pump and it’s fine! Appreciate his kindness and professionalism!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Service

Will start to use periodic servicing

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Service

Comfort Control was very quick to respond to ac unit not working properly. Technician, Vu Tran, was very knowledgeable, took pictures, explained the problem & process to repair. Will use CC again in the future, hopefully not in the near future!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Coil Replacement

Had som issues so it took longer than expected, but overall a great job.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Job Locations
for suwanee, ga

Mark S.

Mark S. Job Checkin

On site found wire connections loose to core sense. Fixed wires tested system is operating and cooling at this time.


Eric R.

Eric R. Job Checkin

$300 tax credit $125 sawnee emc rebate $375 manufacturers rebate


Reece W.

Reece W. Job Checkin

No cool. Found bad capacitor causing condenser to not start. Replaced capacitor and system is cooling at this time. Thank you so much for your business today! It is greatly appreciated! Its customers like you that keep us in business and keep our families taken care of! If you were happy with your service today and you wouldnt mind, please take a few minutes to give us a 5 star review on google! All you have to do is go to google.com and sign into your google account. From there, search for “Comfort Control Heating and Air”. Click on “Reviews”. Write your review mentioning me, Reece Wilson and please be sure to leave 5 stars! Thank you so much and have a great day!


Jon F.

Jon F. Job Checkin

Found clogged drain line. Cleared drain line very well. System cooling at this time.


Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Jordan R.

Jordan R. Job Checkin

Complete 2 system a/c repair and preventative maintenance check. Cleaned outdoor coils and checked all components. All electrical components tested within normal manufacturing spec. The downstairs system is 28 years old and extremely inefficient, replacement is highly recommended. The upstairs system is extremely low on return with only 1-12" R6 return. The system needs return plenum and 2 additional return ducts to vents installed to provide proper efficiency and life of system. The system is also low on charge and leaking from the evaporator coil. Verified the part is covered under warranty but the labor is not


Jordan R.

Jordan R. Job Checkin

A/c repair call. Discovered failed outdoor secondary controller. Replaced under parts warranty. System cooling at this time.


Jordan R.

Jordan R. Job Checkin

Complete 2 system a/c repair and preventative maintenance check. Cleaned outdoor coils and checked all components. All components tested within normal manufacturing spec. Systems do not have drain line water safeties to help prevent flooding in the case of common drain line clogs. System would also greatly benefit from compressor saver hard start kits to reduce stress on compressor and reduce energy consumption on startup which will extend the life of the systems. System cooling at this time.


Jon F.

Jon F. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. 2-year-old a/c. Furnace is 15 years old. Blower has slight layer of dust on it. Changed filter. Capacitor is good. Cleared drain line. System has no back up water safety device. DeltaT between return and supply is 16 degrees. Outdoor system is washed off good has good pressures. And good electrical components. Has no compressor saver or surge protection.


Reece W.

Reece W. Job Checkin

Complete 2 system a/c repair and preventative maintenance check. Found upstairs system not cooling due to compressor not turning on. The system is old and needs to be replaced. The downstairs system was struggling to keep up. Condenser coil was dirty causing high head pressure. Also, the air around condenser was 105 degrees. Recommend upgrading both systems. Sending Garrett out for a consultation.


Jon F.

Jon F. Job Checkin

A/c repair call. On arrival found zone damper working. Possible loose wire for motor. Tightly re wired damper to zone board. Tested both zones more than 5 times. Both open and close like they are supposed to. If the problem occurs again will return to replace zone damper.


Reece W.

Reece W. Job Checkin

Complete 3 system a/c repair and preventative maintenance check. Changed filters. Tested mechanical and electrical components.Cleared upstairs drain line. Tested refrigerant pressures. Found upstairs system slightly low on r410a, recommend either evaporator coil replacement or ac and coil replacement as previously recommended by steve. Recommend hard start kits for main level (to take a load off compressors so they start smoother, run smoother and therefore last longer) and basement systems and surge protection for all equipment to protect equipment from power surges. Systems are cooling at this time. Thank you so much for your business today! It is greatly appreciated!


Jordan R.

Jordan R. Job Checkin

Complete 2 system a/c repair and preventative maintenance check. Tested all components. Discovered main level system functional but slightly undercharged. Added compressor saver to the system. Discovered the upstairs system with leaking outdoor secondary controller. Systems 17 years old. Due to age replacement is highly recommended. Systems cooling at this time


Mark S.

Mark S. Job Checkin

A/c repair call. On site found the main floor system low on refrigerant. Found leak in the liquid line. Repaired leak adjusted pressures. Found filters to be dirty client denied changing has stated he will change them. The system is operating and cooling at this time.


Reece W.

Reece W. Job Checkin

A/c repair call. The customer was having problems with portable dehumidifier draining. Checked the tubing and found no clogs. Tested condensate pump, found no problems. Changed tubing to a different portable dehumidifier provided by the customer.