Got here at 9:00am and had everything done by 5:00. Installed new unit, blew insulation in and cleaned everything up. They were all very nice and friendly. Hobson Heating and Air has always sent very respectful and qualified service technicians out to service us. Very Highly recommend them.
Very nice, explained everything in detail
Response from Comfort Experts Inc.:
Your kind words mean a lot to us. Thanks for the positive feedback.
So very grateful that Wade could come & help us, thank you so much!
Tyler was very efficient and courteous! Thought he knew what the problem was and it worked and got the job done because he knows his job well. Thank You Tyler!
Ian arrived so quickly & was very patient & helpful with my questions. Very appreciative of his help this week.
Great service! Young man did excellent job and went beyond expectations. Been with Hobson Heating And Air for years now and always had great service and very nice and respectful repairmen.
Gave estimates to replace filtration. System
Install 36K heat pump upflow keep current filtration includes code kit and 1300 sq ft R19 insulation
2015 3t hp closet upflow. Expired manufacturers warranty. Oil streaks present and leaks detected in evaporator coil. Filter hasn't been replaced in over a year. Heavy biological growth present inside indoor unit. Electric heatstrips have a heavy layer of biological growth buildup. UV bulb is out. Compressor is compromised due tonthe lack of appropriate charge. Start capacitor pressure cap is cracked. History of capacitor replacement. History of compressor replacement. History of refrigerant recharge. Defrost control board has Heat damage. Low voltage not protected. Vapor line needs better insulation. Insulation needs replenish. Sat with both homeowners and educated on the systems performance, reliability and saftey. Knowing the parts availability is an issue homeowners agreed to a CA appointment 4/15/25 @6p. System restoration estimate built. System functioning but diminishing in performance.
2015 Downstairs Trane Airhandler Checked and tightened all electrical connections Changed Customer provided filters Drain was clear and draining, drainswitch was removed from system by homeowner Blower has slight dust build up Evaporator coil has biological growth build up 2015 Downstairs Trane heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit 2014 Upstairs Trane Airhandler Checked and tightened all electrical connections Changed Customer provided filters Drain was clear and draining Blower has slight dust build up Evaporator coil has biological growth build up 2014 Upstairs Trane heatpump Checked and tightened all electrical connections Dual run capacitor was within m
Upon arrival, technician talked to homeowner technician then started on the condenser. This unit is a straight electric technician found that the 24 V wire was not covered as well. It didn’t have a compressor saver technician suggested insulation over 24 V as well as a compressor saver technician headed to the indoor where technician found a UV bulb that is starting to go out. Technician talk to homeowner about it. Homeowner would like to go with the 24 V protection. It is installed in all the work is done.
Iron filter stuck in backwash. Water was flooding yard. Put filter in bypass to stop water from running. Softener is still on line. No warranty on filtration
We will cable line thru c/o under patio in attempt to clear. This is only an attempt as this home is on a Septic system. If tanks are full, this may not fix the problem. Pulled back several baby wipes on cable. Let customer know that these are not flushable. Any warranty given will be void if wipes are present Inlet side of tank is under screened in porch. Tank is not full.
Main system Airhandler old lennox Checked and tightened all electrical connections Changed Customer provided filter Drain was clear and draining Heatstrips were functional and within manufacture range Blower motor and wheel were acceptable Blower cap was within manufacture range Blower wires have biological growth build up Evaporator coil has heavy biological growth build up Main system straight electric old lennox Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Secondary system airhandler new Lennox Checked and tightened all electrical connections Changed Customer provided filter Drain was clear and draining Heatstrips were functional and within manufacture range Blower motor a
Stoppage in toe lift only. Customer was quoted 89 over phone. No cable was used to clear tub drain. No warranty
12/16/24 TS- cleared clog that was effecting bathroom and kitchen sink from the bathtub drain with 25' snake. Clog was about 10' in. Ran tub and flushed toilet 6+ times and everything is flowing past cleanout in backyard
Home is having airflow issues recommended estimates Cst declined repairs at this time