Mark D.

Mark D. Job Checkin

Arrived to no cool. Found that the 35/5 dual run capacitor had failed. Replaced capacitor, fixed electrical connections and added a compressor saver to help with the efficiency and reliability of the w system. Performed function check. System was cooling the home upon departure.


Mark D.

Mark D. Job Checkin

Down flow straight electric system. All electrical connections are tight with no corrosion. Ecm blower motor is acceptable. Blower wheel and evaporator coil are clean. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Adding a compressor saver is highly recommended to help with the efficiency and reliability of the system.


Don S.

Don S. Job Checkin

Yvyvvyvyvy


katie c.

katie c. Job Checkin


Diane P.

Diane P. Job Checkin

Performed Super tune up. Washed condensor and tightened connections Recommended drain switch, unit surge protector and compressor saver System cool and heat performed good delta Average 19 Inside unit clean in return and supply - inside unit somewhat dirty System left on cool at exit


Crystal P.

Crystal P. Job Checkin


Justin  P.

Justin P. Job Checkin

2015 upstairs Trane airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil was acceptable Heat strips were functional and within manufacture range 2015 upstairs Trane Heat pump Checked and tightened all electrical connections Compressor capacitor is close to tolerance Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out 2013 downstairs Trane Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil was acceptable Heat strips were functional and within manufacture range 2013 downstairs trane heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Refrigerant levels were a


mark.grant@acgenius.com

mark.grant@acgenius.com Job Checkin

2015 Goodman airhandler Checked and tightened all electrical connections Changed customer provided filter Drain was clear and draining Blower motor and wheel were acceptable Blower wires had some biological growth Evaporator coil was acceptable Heat strips were functional and within manufacture range 2015 Goodman heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacturers range Primary electrical unit was acceptable Defrost board was acceptable Defrost is functional Refrigerant levels were acceptable Condenser coil was acceptable Fan blades and motor were acceptable Washed coil from inside out Waxed top of unit Recommended uv system and coil cleaning


Alex  D.

Alex D. Job Checkin

Cleaned all supply and return vents and ducts Also pulled blower wheel cleaned with coil cleaner Cleaned blower cabinet and coil in place


Aaron  W.

Aaron W. Job Checkin

Main unit has heavy biological growth inside system and heavy build up on blower wheel ,garage unit is operating, system has biological growth inside system,, customer has level 2 duct cleaning schedule for tomorrow at 12


Tyler S.

Tyler S. Job Checkin

01/05/24 Tyler S- cleared drain in upstairs master bathroom from shower drain.


Tyler S.

Tyler S. Job Checkin

Standard block in the master bathroom upstairs. Customer is waiting on insurance company or warranty company to cover.


Diego M.

Diego M. Job Checkin

Upon arrival system was turned off with fan on but outdoor unit was still running. Contactor had gotten stuck. Replaced contactor. System turns off when satisfied and when turning off on thermostat. Refrigerant levels are acceptable. Left system in working condition.


Diego M.

Diego M. Job Checkin

Upon arrival system was turned off with fan on.turnung system on refrigeratant levels dropped system started to ice up. Started leak search but unable to find leak. Tried to top it off for the night but did not have enough refrigerant. Schedule us to come back out tomorrow with refrigerant and try leak search again. Leak was from suction line valve. Fixed leak. Topped off system. Left system in working condition.


Steven S.

Steven S. Job Checkin

Upon arrival for service system off. Inspected system. Line for txv had moved out of place stopping the the txv from adjusting properly. Reset line so txv would function properly. Left system on and cooling at departure