Justin has been here 3 or 4 times on my cooling and heating checks on my maintenance plan. He has always been knowledgeable and professional. He also puts up with my looking over his shoulder and questions.
Super tune up performed on a two year old Goodman heat pump package unit. All electrical connections are tight with no corrosion. All amp draws are in range. Compressor and condenser fan motor are acceptable. ECM blower motor is acceptable. Biological growth present inside of the unit. Germicidal UV light installed on this visit to kill existing bio growth and prevent it from coming back. Refrigerant levels are in range. Outdoor unit was washed and waxed.
Replace flapper in half bath toilet
told customer to leave system alone not to flip any breakers or anything when failure happens at time of diagnostic. Everything was working properly. Everything else within manufacture specs and pressures are OK is having an intermittent problem. Will likely return to diagnose system again once problem reappears.
Breaker was turned off. Turned all breakers on and system started cooling
2014 Comfort Maker Airhandler Checked and tightened all electrical connections Changed customer provided filter Drain has slight build up Emergency pan is heavily rusted Blower motor and wheel have dust and dirt build up Evaporator coil has dust and dirt build up Airhandler cabin is HEAVILY RUSTED Supply plenum has heavy biological growth Outside of the supply plenum is heavily rusted 2009 Comfort Maker straight cool Checked and tightened all electrical connections Dual Run cap was within manufacture range Home warranty company recently replaced primary electrical unit Home warranty company recently added hard start kit Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were heavily compacted with dust and dirt build up Cleared debris from the bottom of the unit Washed condenser coils from the inside out Waxed the top of the unit Setup comfort advisor visit and electrical visit for next Wednesday confirmed by offi
Technician found that. The exhaust fan was not Completely up against the sheet rock causinsulation to be sucked in technician pookie around the exhaust fan tech recommends installing 4" duct for fan to go out the ceiling
8/20/25 Unable to complete maintenance on the system due to the rain. Waited two hours for the rain to clear and it would not stop. Tune up completed on propane furnace installed in 2010. Need to reschedule tune up for Monday morning.
We did a duct cleaning blower cleaning and did insulation today
Level 2 duct cleaning and 1100 square feet of r19 attic insulation scheduled for tomorrow morning of August the 12th. Customer paid half down and will pay the remainder upon completion of the work.
Upon technicians arrival technician found drain was clogged technician, clear, drained, and installed antimicrobial pan treatment at this time technician then flushed a gallon of water down the system, and it down up to technician standards
Upon arrival found system operating normally owned out compressor mag compressor. Everything was OK when applied power back to the system. Fan came on but compressor did not check contactor and had 120 coming through contactor found ants in contacts replaced contactor and added a compressor saver. System is running.
Upon technicians arrival technician found that the system looked to be undercharged technician looked for a leak and did not find any leaks at this time technician added a small amount of refrigerant system is properly charged at this time technician would love to give the system a workout
7/28/25 Checked boiler and circulation system for on floor heating. There are wire that are disconnected and covers that are gone off pumps. Customer is checking with the builder to see who installed in floor heat. I checked error code history and found cod F76 which means the boiler and circulating system is not communicating with each other. There are some loose wires on circ board. Me and Mark W. Need to come back first call and trace wires