Overall Experience
Quality
Price
Convenience
Mark D and Tyler B were very professional. Tyler is in the learning phase but was very tentative in learning to do the right way.
Overall Experience
Quality
Price
Convenience
We really appreciated Justin Penningtons attention to detail while servicing our HVAC. He was fantastic
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Hunter was very professional and repaired our AC quickly. Thank you!
Overall Experience
Quality
Price
Convenience
Wade and Zachary were very respectful and knowledgeable. Great work and very professional.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Great service, came out for a quote, did the work as described.
Overall Experience
Quality
Price
Convenience
I will always ask for Justin for anything I have done.
Overall Experience
Quality
Price
Convenience
Both guys are very good mechanic and old time and did great job and have a good personality. The good employees this is from Chess
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Justin has been here 3 or 4 times on my cooling and heating checks on my maintenance plan. He has always been knowledgeable and professional. He also puts up with my looking over his shoulder and questions.
Overall Experience
Quality
Price
Convenience
This is to repair shower steamer and install shut down valves
Customer did not have filters. System has two 18x20x1 filters that needs to be changed as soon as possible. All electrical connections are tight with no corrosion. Evaporator coil and blower wheel are slightly dirty due to dirty air filters. Heat strips are pulling proper amperage. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Outdoor unit was washed and waxed.
Super tune up performed today on a Ducane heat pump installed in 2024 with a Carrier air handler installed in 2019. All electrical connections are tight with no corrosion. X13 blower motor is acceptable. Blower wheel and evaporator coil are clean. Heat strips are pulling proper amperage. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Reversing valve and defrost control board are working as they should boutdoor unit was washed and waxed.
Capacitor on defrost board failed causing low voltage fuse to blow. Replaced board and ran system check. Left with system cooling
Brian needs a day to collect the info gathered and make a good estimate as well as find some good outside timers
Dual run cap failed. Replaced and left with system cooling
Upon arrival for Heating tune up inducer motor would on humans nothing else would happen. Found 2MFD CAP failed and pressure switch failed as well. Replaced both and finished tune up.
Super tune up performed today on a Goodman air handler installed in 2014 with a Goodman heat pump installed in 2021. All electrical connections are tight with no corrosion. Blower wheel and evaporator coil are clean compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Outdoor unit was washed and waxed. 45/5 dual run capacitor was weak and was replaced under warranty. Compressor saver was installed on this visit. Wired attic fan is not working, the motor has failed suggest replacing it with a solar fan. System running. And cooling upon departure.
Super tune up performed on a two year old Goodman heat pump package unit. All electrical connections are tight with no corrosion. All amp draws are in range. Compressor and condenser fan motor are acceptable. ECM blower motor is acceptable. Biological growth present inside of the unit. Germicidal UV light installed on this visit to kill existing bio growth and prevent it from coming back. Refrigerant levels are in range. Outdoor unit was washed and waxed.
Replace flapper in half bath toilet
told customer to leave system alone not to flip any breakers or anything when failure happens at time of diagnostic. Everything was working properly. Everything else within manufacture specs and pressures are OK is having an intermittent problem. Will likely return to diagnose system again once problem reappears.
Breaker was turned off. Turned all breakers on and system started cooling
2014 Comfort Maker Airhandler Checked and tightened all electrical connections Changed customer provided filter Drain has slight build up Emergency pan is heavily rusted Blower motor and wheel have dust and dirt build up Evaporator coil has dust and dirt build up Airhandler cabin is HEAVILY RUSTED Supply plenum has heavy biological growth Outside of the supply plenum is heavily rusted 2009 Comfort Maker straight cool Checked and tightened all electrical connections Dual Run cap was within manufacture range Home warranty company recently replaced primary electrical unit Home warranty company recently added hard start kit Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were heavily compacted with dust and dirt build up Cleared debris from the bottom of the unit Washed condenser coils from the inside out Waxed the top of the unit Setup comfort advisor visit and electrical visit for next Wednesday confirmed by offi