Great service, came out for a quote, did the work as described.
I will always ask for Justin for anything I have done.
Both guys are very good mechanic and old time and did great job and have a good personality. The good employees this is from Chess
Justin has been here 3 or 4 times on my cooling and heating checks on my maintenance plan. He has always been knowledgeable and professional. He also puts up with my looking over his shoulder and questions.
Alex was very courteous and respectful! Explained the plan and ask me if I had any questions. No complaints at all!!!
Kellen was sooo great! I couldn't make the app work!! Will you please do that for me???thank you? Helen😊
Adding 16" damper and two sheet metal scoops
He currently has no issues but I did talk to him about the fact that since he has two meters he most likely is paying a flat fee on both of them and if he was interested in possibly getting one of those rerouted to the main panel on the pole but he is not at this time
Customer states that the two bedrooms are very warm. Customer recently added an addition to the home and has uneven air flow. New duct work was added to most of the home except for the two bedrooms. Air is bypassing the bedroom ducts and favoring the main 16 inch duct that is feeding the new plenum to the rest of the house. Comfort advisor is scheduled to meet with the customer regarding re engineering the duct work and do a load calculation of the home to ensure the unit is sized properly for the addition. Customer has $120 credit he would like to put toward repairs.
Closet downflow. Compressor short. Trips 40amp breaker. Indoor unit on a 70amp breaker. Heavy airflow restriction on evaporator coil. Blower extreme buildup. Compressor OHM verified short. Disconnect is bypassed by another company. Dual run cap had melted last night per homeowner. Homeowners agreed to have CA call for a pre approval. CA appointment set for 6/3/25. System down, children in home.
Upon arrival tech found that home owner had stepped through the return technician went under the house and put it back together the system is operating properly at this time
2018 Goodman Airhandler Main Checked and tightened all electrical connections Filters were recently changed Filter is wrong size, filter box is for 20x25x1 Drain was clear and draining Blower motor and wheel have slight biological growth build up Evaporator coil was acceptable 2018 Goodman Heatpump Main Checked and tightened all electrical connections Dual run capacitor is weak Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from bottom of the unit Washed condenser coils from inside out Waxed top of the unit 2018 Goodman Airhandler Master Checked and tightened all electrical connections Filters were recently changed Filter is wrong size, filter box is for 20x25x1 Drain was clear and draining Blower motor and wheel have slight biological growth build up Evaporator coil was acceptable 2018 Goodman Heatpump Master Checked and tightened all electr
Pawn technicians arrival technician found that master bedroom system was down tech found the fan motor was not running technician found that there was a stick that had fallen down it's blocking the fan from moving tech omh the fan motor everything is coming back okay right now technician is talking to homeowner explaining that thing could go out in the future tech found everything else to be running properly at this time Tech does recommend home owner changing out filters
Upon arrival customer informed that home inspection found a split 11 degrees ran system for 20 mins and had a 19.5 degree split.
I have replaced the breaker and wire going to the condenser to comply with the data tag
ELECTRICAL TO HVAC Need a tech to look over his system tomorrow afternoon at the request of house inspection Me and Jake will return tomorrow to install new wire and a breaker for the compressor 50 amp and 8 wire general electrc breaker
Tech talked to homeowner and explained everything that happens and what need to happen
Technician found bracket to blow motor is broken technician has a comfort advisor coming out went homeowner is available technician installed new bracket and found blower bearings are done there is going to need to be a x13 blower motor ordered whenever technician talks to homeowner
Quoted a level 3 42k heat pump closet upflow for $16,194