1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for rhome, tx

Rated 4.9 out of 5 stars based on 12 customer reviews

Excellent service!

Very professional and knowledgeable young man. Very pleasant and polite.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very Courteous

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

I was so pleased to have Derek come out to check our plumbing. He was able to fix all the issues we had. Derek was very pleasant to talk to. We will request him for all our other plumbing needs.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very knowledgeable and friendly

This company will take care of all your needs and fast.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Thank you for the care that is taken when working on our unit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Explained everything and did a great job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fabulous service

Ryan was fabulous! He could not have been better

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome employees

They did a great job and left everything clean and tidy

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Great experience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for rhome, tx

adam.brockelman@acgenius.com

adam.brockelman@acgenius.com Job Checkin

Arrived onsite and removed the hose bibb at the end of home per the customers request. Tested after repairs were made everything working properly.


katie c.

katie c. Job Checkin

Arrived to address a persistent leak under the kitchen sink caused by a worn-out pipe joint. After carefully inspecting the area, I discovered the seal had deteriorated and replaced it with a durable, high-quality fitting. Once the repair was complete, the leak was resolved and water was flowing smoothly again.


Justin  P.

Justin P. Job Checkin

2018 Amana airhandler Checked and tightened all tightened all electrical connections Changed Customer provided filter Drain had some build up in trap Heat strips were functional and within manufacture range Blower motor and wheel were acceptable Evaporator coil was acceptable Condensate pan has biological growth build up Uv system is no longer functional 2018 Amana Heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended anti microbial pan treatment for drain as well as uv upgrade and compressor saver


adam.brockelman@acgenius.com

adam.brockelman@acgenius.com Job Checkin

Inspected hose bibb she said she was having issues with. That valve is working properly. Went ahead and rebuilt a toilet I hall bathroom by front door. Tested after repairs were made everything working properly.


Lisa M.

Lisa M. Job Checkin


Justin  P.

Justin P. Job Checkin

2023 intertherm airhandler Checked and tightened all electrical connections Customer recently changed filters Heatstrips were functional and within manufacture range Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil was acceptable Airhandler door has slight air leak Recommended weather strip to prevent unfiltered air into system 2023 ducane straight electric Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended pan treatment for drain and compressor saver


Mark D.

Mark D. Job Checkin

11/21/24 Problem going into heat pump mode. Have fixed temporarily but would like to return Monday morning to further evaluate the issue. Please set up a return visit for Monday first call.


hunter.gill@acgenius.com

hunter.gill@acgenius.com Job Checkin

Upon arrival, technician was shown to air handler condenser and thermostat. Technician started at the condenser where tech washed and waxed unit after technician got inrush of 132 which is above data tags limit. It has gone up over the year. Tech looked at previous pictures. Tech is recommending a compressor saver, which will lower it by 40%. Technician checked fan motor as well as compressor both were looking OK and up to technician standards. Technician headed up to attic tech pulled filter out. It was a little dirty technician didn’t see another filter to replace it with. Everything inside the air handler looked clean and up to technicians standards. Technician talk to homeowner about a compressor saver and explain the purpose of it. Husband wasn’t home. Technician will send a invoice of the compressor saver and let them decide.


katie c.

katie c. Job Checkin


Cody B.

Cody B. Job Checkin

Tech Cody arrived to customer's home and met the homeowner. When I arrived the thermostat was callingmfor cool but the system would not kick on. The outdoor control board was giving me the 04 error code for locked rotor, I diagnosed a failed capacitor which was causing the code to show. I shared my findings with the homeowner and replaced the part under warranty P&L. Once replaced I turned power back on to the unit and the system began to cool. The compressor and fan motor were operating within manufacturer range and the refrigerant charge was at acceptable levels at this time. I also replaced the filter while I was there and saw that the indoor coil and blower were clean and the UV light was functioning properly. System was cooling when i left.


mark.grant@acgenius.com

mark.grant@acgenius.com Job Checkin

2012 Goodman airhandler Checked and tightened all electrical connections Customer changed recently changed filters Drain was clear and draining Blower motor and wheel were acceptable blower wires have biological growth build up Evaporator coil was acceptable 2012 Goodman Heatpump Checked and tightened all electrical connections Dual run capacitor was out of manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended uv system for biological growth, replacement of Dual run capacitor and compressor saver


adam.brockelman@acgenius.com

adam.brockelman@acgenius.com Job Checkin

9/10/24 Arrived onsite customer said her child has Covid needs to reschedule for a different day.


Robert G.

Robert G. Job Checkin

No quote


Jerred G.

Jerred G. Job Checkin

Etu. Recommended whole home surge protection. Recommended repairing service entrance conduit into meter socket to prevent future problems. Emailed estimate and spoke to customer about upgrading membership. Customer would like an email regarding home budget protection plan.


Zak L.

Zak L. Job Checkin

Arrived for service Eval Downstairs compressor cap failed Temp replacement to check system Low refrigerant Comfort Advisor tomorrow 3pm to replace system