Very professional and knowledgeable young man. Very pleasant and polite.
I was so pleased to have Derek come out to check our plumbing. He was able to fix all the issues we had. Derek was very pleasant to talk to. We will request him for all our other plumbing needs.
This company will take care of all your needs and fast.
Thank you for the care that is taken when working on our unit.
Performed all work described in estimate tested after repairs were made everything working properly. Need to return at a later date with correct fitting to connect icemaker to valve under sink. Customer already paid for it no charge JOB IS FINANCED DOCUMENTS SIGNED
Schedule project for next Tuesday all day long
Recommended Work completed by Hunter G
Upon Arrival tech installed Compressor saver As well as low voltage protection
Upon technicians arrival technician found that everything is working perfectly fine. Unit is working how it is supposed to heat pump is working properly. Thermostat was set to 69. The house was 69° inside when technician arrived technician had a homeowner bump it up to 72 system met desired temperature inside. At this time system is working as intended.
Arrived onsite customer has a water loss occurring at the meter. Wrote estimate for leak locating problem area. Once leak is found we can write estimate to fix the issue.
This is a inverter system makes a td in cooling of 20°. In heating is 30. The system works efficiently and runs well. It does have major corrosion going on in the air handler. The system is rusting away at the blower motor and the supply box is pretty covered in bio growth. The heat strips as well are very badly covered in rust. I recommend we replace the heat strip package along with the blower motor wheel and housing. In doing so I can clean up the system with everything out in the open. I recommend a uv light for the supply box as well. He wants to talk system replacement this Saturday first call at 10 am.
Arrived onsite and removed the hose bibb at the end of home per the customers request. Tested after repairs were made everything working properly.
Arrived to address a persistent leak under the kitchen sink caused by a worn-out pipe joint. After carefully inspecting the area, I discovered the seal had deteriorated and replaced it with a durable, high-quality fitting. Once the repair was complete, the leak was resolved and water was flowing smoothly again.
2018 Amana airhandler Checked and tightened all tightened all electrical connections Changed Customer provided filter Drain had some build up in trap Heat strips were functional and within manufacture range Blower motor and wheel were acceptable Evaporator coil was acceptable Condensate pan has biological growth build up Uv system is no longer functional 2018 Amana Heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended anti microbial pan treatment for drain as well as uv upgrade and compressor saver
Inspected hose bibb she said she was having issues with. That valve is working properly. Went ahead and rebuilt a toilet I hall bathroom by front door. Tested after repairs were made everything working properly.
2023 intertherm airhandler Checked and tightened all electrical connections Customer recently changed filters Heatstrips were functional and within manufacture range Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil was acceptable Airhandler door has slight air leak Recommended weather strip to prevent unfiltered air into system 2023 ducane straight electric Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended pan treatment for drain and compressor saver
11/21/24 Problem going into heat pump mode. Have fixed temporarily but would like to return Monday morning to further evaluate the issue. Please set up a return visit for Monday first call.