Job Locations
for aberdeen, nc

Bradley M.

Bradley M. Job Checkin

Complete: 2 systems worked on US system Heil Split HP: HO said was cooling great and suddenly stopped cooling. At the HP found bad 30/3 cap. Had to add dual 30/5 and a 3mfd run. Checked charge and system is running great at this time.


Bradley M.

Bradley M. Job Checkin

Complete two systems, worked on downstairs unit, Goodman split heat pump. Found 10 mfd bad in crawl space. System is operating properly at this time.


Bradley M.

Bradley M. Job Checkin

Complete 2 systems worked on DS Unit Goodman split HP: HO said stopped cooling. Found 10mfd bad in crawl space also found couch pushed up against return. Checked vents and had 54° coming out and temp dropped 3° while I was there. SH was at 27°. System is working great at this time.


Bradley M.

Bradley M. Job Checkin

Incomplete: 1 system Bryant split HP: HO had a representative there for her. He said it was out of refrigerant. So I went to the HP and sure enough it was bone dry.


Benjamin R.

Benjamin R. Job Checkin

Complete two systems, Goodman heat pumps, worked on upstairs unit. Found bad dual capacitor and replaced it. Also changed p-trap. System is operating properly at this time.


Bradley M.

Bradley M. Job Checkin

Complete: Came to replace Tstat and EIM. Replaced rewired and setup Tstat. System is operating as it should at this time. The Tstat Kit came with an EIM so we can return the other we purchased.


Ron M.

Ron M. Job Checkin

American standard ac check


Ron M.

Ron M. Job Checkin

Goodman ac check


Benjamin R.

Benjamin R. Job Checkin

Replacing a blower motor on a Nordyne electric furnace


Benjamin R.

Benjamin R. Job Checkin

Working on a Bryant gas pack


Dror S.

Dror S. Job Checkin

Goodman and train heat pump cooling maintenance


Bradley M.

Bradley M. Job Checkin

Complete: 2 systems worked on DS Unit: Trane Split HP: HO said wasn’t cooling any longer. Found HP not working checked under the house and found condensate pump had gfi tripped due to clogged line. Unclogged line and reset gfi and system came on. Condensate pump is working. System is working as well.


Bradley M.

Bradley M. Job Checkin

Complete: 2 Systems worked on US Unit: Trane split HP: When we arrived HO said the system wasn’t blowing cold air and that the breaker was tripped. At the HP found dead compressor


Benjamin R.

Benjamin R. Job Checkin

Working on a Goodman heat pump


Bradley M.

Bradley M. Job Checkin

Complete: 2 System: EPA Maintenance Goodman Split Heat Pump: US Air Handler: Checked Thermostat and Capacitor, Filters and Amp Draws on the Blower Motor, Inspected Evap coil. Replaced P-Trap, checked condensate line. Heat Pump: Checked the charge, and the capacitor. Check the Amp draws on the fan and compressor. Cleaned Unit. Washed Coils System looks good and running Great at this Time.