Benjamin R.

Benjamin R. Job Checkin

Working on 2 Trane heat pumps


Benjamin R.

Benjamin R. Job Checkin

Cleaning a drain line on a Goodman air handler


Benjamin R.

Benjamin R. Job Checkin

Working on a Arcoaire heat pump


Benjamin R.

Benjamin R. Job Checkin

Replacing a control board on a Carrier air handler


Benjamin R.

Benjamin R. Job Checkin

Working on a Goodman heat pump


Andrew B.

Andrew B. Job Checkin

Water coming through vent Found drain line stopped up


Benjamin R.

Benjamin R. Job Checkin

Working on an Amana heat pump


Benjamin R.

Benjamin R. Job Checkin

Routine maintenance on Trane heat pump


Bradley M.

Bradley M. Job Checkin

Complete: 1 System 2 Zone Heil Split HP: HO said wasn’t coming on at all. At the AH in the crawl space found System shut off by the condensate pump. Found tubing clogged and tripped breaker to condensate. Blew out tube, cleaned Ptrap and system came on perfect. Checked charge and system is working great at this time.


Bradley M.

Bradley M. Job Checkin

Complete: 1 system Goodman split hp: HO said had no signal on Tstat. At AH found blown fuse. Traced short back to reversing valve solenoid. Was going to get a solenoid from East Coast but called Jimmy and he had one in Warehouse Stock. He delivered it. The HO had to leave so we put new solenoid on and tested the unit from the outside.


Benjamin R.

Benjamin R. Job Checkin

Installing a UV light on a Goodman air handler


Bradley M.

Bradley M. Job Checkin

Incomplete 1 System Worked on a Goodman Heat Pump Split System HO said Unit was not keeping desired temperature . Evap. Coil and outside sunction lune was freezing up. Found Unit way too low in refrigerant. Unit holds 14 lbs. and 8 oz of R22 so we started a leak search but when we started rain started pouring a lot of rain. Left nitrogen at 290 psig. Need to reschedule to continue leak search. Spoke with HO completely understands and he thinks they might have been low in refrigerant for some time


Benjamin R.

Benjamin R. Job Checkin

Working on a Rheem heat pump


Benjamin R.

Benjamin R. Job Checkin

Routine maintenance on Payne heat pump


Skyler H.

Skyler H. Job Checkin

Goodman split heat pump no cool