7001 Lark Lane
Sanford, NC 27332
(919) 777-1777

Our Top Cities


Local Reviews
for chapel hill, nc

Rated 5.0 out of 5 stars based on 17 customer reviews

Great service

I thought the AC install is a two day project but they completed in less than a day and Joshua does know what he was doing. I’m impressed with the service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Did an excellent job!

Excellent. He was prompt, worked hard, explained what he was doing. Appears very knowledgeable and experienced. Highly recommended.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional

Easy to deal with, very personable and professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Happy 😃

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic service and explanation of work done

Fantastic service and explanation of work done

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

They worked with AHS warranty which is not great for them but delivered excellent service Appreciate their assistance and was professional and careful during COVID times.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

My experience with Joel Worshama and team from Comfort first Heating and Cooling (Sanford) was fantastic, perfectly fixed with professional ism and manerism, excellent Job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Comfort First came on behalf of American Home Shield to resolve a problem with the ac and took care of it fast. The tech was very courteous and right on time.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fall Service

Tony checked out all 3 of our units. Found problem with new system. Reported it already, parts on order. Our 2 older systems are ok. Thank you Tony.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for chapel hill, nc

Tony M.

Tony M. Job Checkin

Heating maintenance


Tony M.

Tony M. Job Checkin

Heating maintenance


Manuel M.

Manuel M. Job Checkin

Complete 2 System worked on both Systems. Main Unit 2 Zones, 1rst and 2nd Floor. Lennox 90% Gas Furnace: EPA Heating Maintenance: Checked tstat and air filter. Checked electrical connections. Checked blower motor amp draws. No CO detected. Burners are clean. Cleaned flame sensor. Checked all pressures hoses. Checked amparage on draft motor. All safety switches are on great condition. System is running great at this time. 3rd Floor Fijutsi Mini Split EPA Heating Maintenance: checked blower motor. Inspected evap coil. Checked air filter. Checked compressor amp draw and cfm. Checked pressures. Condenser is clean. System is running great st this time.


Manuel M.

Manuel M. Job Checkin

Complete 2 Systems worked on DS Trane Straight A/C: HO stated tstat went blank. Found Condensate pump gfi tripped. Reset it. Pump is working properly. Also found service door to furnace not installed correctly. Door was not making contact with power switch with on furnace. Checked pressures. System is running great st this time.


Manuel M.

Manuel M. Job Checkin

Complete 1 System Goodman Gas Pak. EPA Heating Maintenance: cycled system. Checked tstat and air filter. Checked electrical connections. Checked blower motor and run cap. Found weak run cap. Reading 6.2 out of 10 uf. Replaced it authorized by HO. Charged her Level 1 + tax. System still under the 10 year parts warranty. Inspected evap coil. No CO detected. Burners are clean. Cleaned Flame sensor. Checked amparage on draft motor. All safety switches are on great condition. Checked draft motor. System is running great at this time.


Tony M.

Tony M. Job Checkin

Trane ac. Low charge


Tony M.

Tony M. Job Checkin

Goodman furnaces maintenance


Nathan T.

Nathan T. Job Checkin

Lennox gas furnace bad zone board


Manuel M.

Manuel M. Job Checkin

Complete 1 System Trane HO Split System. HO stated pvc pipe (1 1/2”) slipped out after I left. More likely hose coming from boiler which goes into same drain ad the hvac, pushed it drain down reason why drain slipped out. Added a strap to get more support to drain. Added more pvc pipe to drain (1 1/2”) and a coupling. Used primer and glue to get pvc secured. Checked again to make sure drain was clear. System is running great at this time.


Manuel M.

Manuel M. Job Checkin

Complete 1 System Trane HO Split System. HO stated pvc pipe (1 1/2”) slipped out after I left. More likely hose coming from boiler which goes into same drain ad the hvac, pushed it drain down reason why drain slipped out. Added a strap to get more support to drain. Added more pvc pipe to drain (1 1/2”) and a coupling. Used primer and glue to get pvc secured. Checked again to make sure drain was clear. System is running great at this time.


Manuel M.

Manuel M. Job Checkin

Complete 2 Systems worked on US Payne Straight A/C: replaced case coil. Recovered ref. To remove ductwork and case coil took us more time than usual due them having a bunch of screws and probably a 1/4 inch layer of mastic that was hard as cement. Removed old coil. Installed new case coil. Had to repipe copper lines and drain line. Leak tested system. Pulled vacuum. Added 7 lbs of 410A.


Manuel M.

Manuel M. Job Checkin

Incomplete 2 Systems worked on US Payne Straight A/C: HO stated system was not cooling. Found system low in ref. 3rd time. Performed a leak search. Found leak at the evap. Coil. System holds 7 lbs of 410. 3 ton Up Air Flow Payne Case Coil. Case coil dimensions: 17.5Width x 17Height x 17.5Depth. Will need to order case coil from East Coast. Didnt order due time being after 5.


Carl T.

Carl T. Job Checkin

Trane A/C and gas furnace checked system found very dirty air filter causing duct work to make noice qhen system comes on


Manuel M.

Manuel M. Job Checkin

Complete 3 Systems worked on DS Trane Straight A/C: HO stated system was not cooling. Found drain line stopped up. Float switch at the secondary drain plug was cutting system off due to main drain plug being stopped up. Replaced p trap and clear line. Tested condensate pump. Checked pressures. System is running great at this time


Manuel M.

Manuel M. Job Checkin

Complete 1 System Straight A/C: HO stated system was not blowing any air. Found bad run cap. Replaced it with a 5uf from truck stock. Found system low in ref. Added 1 lbs of R22. System is running great at this time.