I thought the AC install is a two day project but they completed in less than a day and Joshua does know what he was doing. I’m impressed with the service
Excellent. He was prompt, worked hard, explained what he was doing. Appears very knowledgeable and experienced. Highly recommended.
Fantastic service and explanation of work done
They worked with AHS warranty which is not great for them but delivered excellent service Appreciate their assistance and was professional and careful during COVID times.
My experience with Joel Worshama and team from Comfort first Heating and Cooling (Sanford) was fantastic, perfectly fixed with professional ism and manerism, excellent Job
Comfort First came on behalf of American Home Shield to resolve a problem with the ac and took care of it fast. The tech was very courteous and right on time.
Tony checked out all 3 of our units. Found problem with new system. Reported it already, parts on order. Our 2 older systems are ok. Thank you Tony.
Fast service and technician was very professional and had a great personality. Resolved the problem quickly and explained what he repaired. Excellent!
Appeciated the quick appointment, and Cody arriving on the early side of the appointment window! He was professional, knowledgable about other service questions I had, and fixed the problem with no further issues.
Tony was great! Professional and explained everything well. Knew exactly what he was doing!
Ducane gaspack cooling maintenance
Complete 1 System Amana HP Split System Replaced defrost board. Tested. System is working great at this time.
Complete 3 Systems 3 EPA Cooling Maintenances. Main Floor/Main Unit. Amana HP Split System. Checked tstat and air filter. HO requested us to bring air filters with us for this unit at every Maintenance time. System has 2 16x16 and 1 16x20 air filters. HO will be paying for them every time. I mentioned the air purifier filter that has to be replaced every year, he stated he will think about it. Checked blower amp draw and run cap. Inspected all wiring at the AH. Inspected evap coil. Drain line found clear. Checked compressor and cfm amp draws. Installed New Surge Protector Authorized by HO. Used surge protector from truck stock. Charged HO the special, $150 + tax. Checked pressures. Inspected all wiring at the condenser unit. Checked dual cap. Cleaned condenser coil. System is running great at this time. Front Sun Room Amana Ptac System. Checked tstat and air filter. Checked blower amp draw and run cap. Inspected all wiring at the Unit. Inspected evap coil. Drain line found
Complete 3 Systems 3 EPA Cooling Maintenances. US Left Side Amana HP Split System. Checked tstat and air filter. Checked blower amp. Inspected all wiring at the AH. Inspected evap coil. Drain line found clear. Checked compressor and cfm amp draws. Checked pressures. Inspected all wiring at the condenser unit. Checked dual cap. Cleaned condenser coil. System is running great at this time. US Right Side Trane HP Split System : Checked tstat and air filter. Checked blower amp draw and run cap. Inspected all wiring at the AH. Inspected evap coil. Drain line found clear. Checked compressor and cfm amp draws. Checked pressures. Inspected all wiring at the condenser unit. Checked dual cap. Cleaned condenser coil. System is running great at this time. DS Main Floor Multi zone System, Trane Straight A/C: Checked tstat and air filter. Checked blower amp draw and run cap. Inspected all wiring at the furnace. Inspected evap coil. Drain line found clear. Checked compressor and cfm amp dr
Complete 2 Systems worked in DS Payne Gas Furnace: HO stated they had an outage last week ever since ds system stoped working. Found blown out 3 amp fuse. Searched for short. Found shorted out tstat. Replaced it. Used a ProSelect prog tstat from truck stock. Replaced 3 amp fuse. Cycled system. System is running great at this time.
Complete 2 Systems 2 Heating Tune Ups. US Carrier HP Split System: Checked tstst and air filter.. Checked heat strips and made sure they were on. Checked blower motor amp draws and run cap. Inspected evap coil. Reccomended a Secondary float switch to HO. Checked all wiring at the AH. Checked compressor and cfm amp draws. Checked dual cap. Dual cap is weak. Needs to be replaced. Checked all wiring at the condenser. Checked pressures. Tested defrost board. condenser coil is clean. System is running great st this time. HO said before calling her home warranty she wanst to know her options towards a new system. Sent Beth Lead sheet. AH is located in the attic. Easily accessible, left to right air flow. Duct is in good condition. Spoke to HO about the 10 year P&L. DS Carrier HP Split System: Checked tstst and air filter. Found bad tstat. System is coming on, and it showes auxilary heat is on but tstat is not sending 24v to relay for heat strips to come on. Tstst needs to be repl