7001 Lark Lane
Sanford, NC 27332
(919) 777-1777

Local Reviews
for elon, nc

Rated 4.8 out of 5 stars based on 5 customer reviews

Great Service -

Explained my new system to me that I could understand before leaving Took their time and didn't rush made sure everything was cleaned up

  • Overall Experience
  • Quality
  • Price
  • Convenience

Honest, Professional Service

Technician was very knowledgeable and courteous. Seemed very thorough!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Worth every penny for the piece of mind of a service contract

Billy did a great job and answered all my questions. He went above and beyond by ensuring my condensate line was clear...which is was not and was actually buried. Awesome service from Billy...he represented the company perfectly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt, Friendly Service!

Both Anna and Billy were very helpful. Thank you both for your prompt and courteous service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great customer service

Billy was awesome. I really appreciate the way he explained everything to me and even took the time to show me pictures. I definitely trust his judgement and that means a lot because a lot of companies take advantage. I have always had great experience with this company as a whole

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for elon, nc

Nathan T.

Nathan T. Job Checkin

Carrier split heatpump found grounded compressor


Manuel M.

Manuel M. Job Checkin

Complete 2 Systems 2 AHS Heating Maintenance Worked on Both Systems. US Goodman HP Split System, AHS Heating Maintenance: Checked tstst and air filter. Replaced air filters. Provided by HO. Checked heat strips and made sure they were on. Checked blower motor amp draws and run cap. Inspected evap coil. Checked all wiring at the AH. Checked compressor and cfm amp draws. Checked dual cap. Checked all wiring at the condenser. Checked pressures. Found low in ref. It could take 2 to 3 lbs of 410A. Pressure reading was 50 psi on suction and 290 on head pressure. Tested defrost board. Rinsed condenser coil. DS Goodman HP Split System: AHS Heating Maintenance: Checked tstst and air filter. Replaced air filters provided by HO.Checked heat strips and made sure they were on. Checked blower motor amp draws. Inspected evap coil. Checked all wiring at the AH. At the Condenser Unit, found compressor not running. Checked dual cap. Condenser fan is working, amp draws are ok. Rinsed condenser coil. T


Manuel M.

Manuel M. Job Checkin

Complete 2 Systems worked on System controlling left side of house. HO stated On Maintenance run cap was found weak and needed replaced. Found weak run cap. Old one reading 7.2 out of 10 uf. Replaced it with a 10 uf. Used a truck stock cap. Cycled system. System is running great at this time.


Manuel M.

Manuel M. Job Checkin

Complete 2 Systems worked on Us Goodman HP Straight A/C: HO stated system outside was not cooling. Found bad contactor. Used a 1 1/2 Plle contactor from trock stock. Found system 2 lbs low in ref. Added 2 lbs of 410A and a leak seal. System is running great at this time.


Manuel M.

Manuel M. Job Checkin

Complete 2 Systems worked on US Goodman Straight A/C: HO stated system was not cooling. Found bad dual cap at the condenser. Used a 35/5 cap from truck stock. Checked pressures. System is running great at this time.


Tony M.

Tony M. Job Checkin

Goodman ac.....replaced evap/coil


Tony M.

Tony M. Job Checkin

Goodman hp not cooling


Tony M.

Tony M. Job Checkin

Goodman hp no cooling


Tony M.

Tony M. Job Checkin

Fan running constantly


Tony M.

Tony M. Job Checkin

Goodman no heat


Carl T.

Carl T. Job Checkin

Goodman replaced compressor and cycled systems working at this time


Juan S.

Juan S. Job Checkin

3.5 tons amana heat pump pack


Juan S.

Juan S. Job Checkin

Ac and coil 2.tons


Carl T.

Carl T. Job Checkin

Trane A/C checked system found to dual run capacitor and replaced and cycled system working at this time


Carl T.

Carl T. Job Checkin

Airease replaced heat exchanger and cycled system working at this time