Complete: 2 Systems: Worked on Upstairs Unit: Lennox A/C Gas Furnace. Came to change out Evap coil. Pumped unit down and Upon entering the attic found secondary pan full of water, tested float switch and it was broken. On the back side of the unit water was running over the pan onto the attic floor (Pic in Docs). Pumped water from pan. Found drain pan line clogged as well as primary condensate line clogged. Informed HO of our findings and she showed me water damage on her ceiling. She said it had been going on for sometime. I took pics of damage to ceiling (Pics in Docs). And asked HO to sign Release if liability form. (Pic in Docs)Blew both lines out and repiped both after remove and installing new Evap coil. Installed new float switch. Turned unit on and it looks good and running as it should at this time. HO also said last tech out smelled gas in the attic and he turned gas off. Said he would check it when he got back. I do not have pipe dope on my van. Could not perform leak search


Mike P.

Mike P. Job Checkin

Replaced 14 inch return flex


Mike P.

Mike P. Job Checkin

Lennox added hard start capacitor and 1 lbs R-22 refrigerant


Tony M.

Tony M. Job Checkin

Goodman AC bad thermostat replace teeth that system working properly


Mike P.

Mike P. Job Checkin

CARRIER HP bad capacitor


Andy S.

Andy S. Job Checkin

Checked Cariier heat pump/found bad Dual capacitor-replaced-checked refrigerant levels-operation good ! Thank you


Tony M.

Tony M. Job Checkin

Goodman AC to lb low R22


Carl T.

Carl T. Job Checkin

Bryant heat pump checked system found bad dual run capacitor and replaced with 40/5 capacitor and cycled system working at this time


Carl T.

Carl T. Job Checkin

Carrier A/C checked system found to be working and maintaining temperature at this time with no machinal issues


Carl T.

Carl T. Job Checkin

Carrier ac recharged system with 6 on R-407C and cycled system working at this time


Carl T.

Carl T. Job Checkin

Lennox A/C checked system and adjusted sub cooling and cycled system working at this time


Carl T.

Carl T. Job Checkin

Ducane ac replaced compressor bi flow drier capacitor and recharged system with 8 pb R438 refrigerant


Tony M.

Tony M. Job Checkin

2 system Trane AC cooling tune up


Tony M.

Tony M. Job Checkin

Amana package unit Tempstar straight ac cooling tune up


Tony M.

Tony M. Job Checkin

Lennox equipment replace second floor blower motor