Heating maintenance


Mike P.

Mike P. Job Checkin

Low in refrigerant


Mike P.

Mike P. Job Checkin

Replaced cfm on Lennox A/C


Carl T.

Carl T. Job Checkin

Goodman ac checked system found to be low in refrigerant and added 1 lb R-22 to system and cycled system working at this time


David L.

David L. Job Checkin

Repaired a Goodman heat pump by replacing the compressor and recharged system


Mike P.

Mike P. Job Checkin

EPA maintenance


Mike P.

Mike P. Job Checkin

Upstairs clogged drain line Downstairs Goodman A/C found bad compressor


David L.

David L. Job Checkin

Repaired a Goodman heat pump by replacing the p trap and added 1 lb freon


Mike P.

Mike P. Job Checkin

Cooling maintenance


Tony M.

Tony M. Job Checkin

Carrier straight AC 1 pound low HSA customer


Tony M.

Tony M. Job Checkin

Lennox AC Frozen coil r410


Tony M.

Tony M. Job Checkin

Lennox straight AC approximately one and a half pound low R22 Define refrigerant


Bradley M.

Bradley M. Job Checkin

Complete: 2 Systems: Worked on Upstairs Unit: Lennox A/C Gas Furnace. Came to change out Evap coil. Pumped unit down and Upon entering the attic found secondary pan full of water, tested float switch and it was broken. On the back side of the unit water was running over the pan onto the attic floor (Pic in Docs). Pumped water from pan. Found drain pan line clogged as well as primary condensate line clogged. Informed HO of our findings and she showed me water damage on her ceiling. She said it had been going on for sometime. I took pics of damage to ceiling (Pics in Docs). And asked HO to sign Release if liability form. (Pic in Docs)Blew both lines out and repiped both after remove and installing new Evap coil. Installed new float switch. Turned unit on and it looks good and running as it should at this time. HO also said last tech out smelled gas in the attic and he turned gas off. Said he would check it when he got back. I do not have pipe dope on my van. Could not perform leak search


Mike P.

Mike P. Job Checkin

Replaced 14 inch return flex


Mike P.

Mike P. Job Checkin

Lennox added hard start capacitor and 1 lbs R-22 refrigerant