Billy did a great job explaining what was wrong with my air conditioning unit and even listed options that could be done and the outcomes of each option. Thanks.
Complete 1 System Goodman HP Split System: EPA Cooling Maintenance. Checked tstat and air filter. Checked blower amp draw and run cap. Inspected all wiring at the AH. Inspected evap coil. Drain line found clear. Checked compressor and cfm amp draws. Checked pressures. Inspected all wiring at the condenser unit. Checked dual cap. Cleaned condenser coil. System is running great at this time.
Complete 1 System Trane 80% GF. Heating Maintenance: cycled system. Checked tstat and air filter. Removed 4 14x14 air and 1 14x20 air fulters due to being way too dirty. HO stated she will new ones this afternoon. Offered her the 2410 air putifier, so she could change air filter once a year. She stated at the moment she was not interested. Checked Blower Motor amp draw and run cap. Checked electrical connections. No CO detected. Cleaned Burners. Cleaned Flame sensor. Checked amparage on draft motor. All safety switches are on great condition. System is running great at this time.
Trane gas furnace found bad control board
Complete 1 System 2 Zones Coleman 80% Gas Furnace: AHS Heating Maintenance: Checked tstat and air filter. Checked motor dampers and made sure theybwere working properly. Checked Blower Motor amp draw. Checked electrical connections. No CO detected. Burners are clean. Cleaned flame sensor. Checked amparage on draft motor. All safety switches are on great condition. System is running great at this time.
Complete 1 System Carrier Straight A/C: came to replace compressor. Recovered ref. Removed old comp. installed new comp. repiped copper lines. Installed new filter dryer. Replaced core valves. Replaced dual cap. Used a 35/5 cap from truck stock. Leak tested system. Pulled vacuum. Added 6 lbs of 438A. Tested system. System is running great at this time.
Complete 1 System Comfortmaker HP Split System AHS Heating Maintenance: Checked tstst and air filter. Checked heat strips and made sure they were on. Checked blower motor amp draws and run cap. Inspected evap coil. Checked all wiring at the AH. Checked compressor and cfm amp draws. Checked dual cap. Checked all wiring at the condenser. Checked pressures. Tested defrost board. Inspected condenser coil. System is running great at this time.
Goodman gas pack checked system found to be completely out of refrigerate and preferred leak search and found leaking evap coil need to replace coil
Trane A/C checked system found bad condenser fan motor
Trane and Amanna A/C completed EPA cooling maintenance and also completed minor duct repaor and cycled system working at this time
Goodman gas packed checked system found rusted thought heat exchanger need to replace heat exchanger
Complete one system check. System operating properly at this time.