Trane Heat pump replaced compressor amd cycled system working at this time
Complete 2 System worked on both MainFloor Left Carrier Straight A/C and Basement/Floor Carrier Straight A/C. Came to perform EPA Cooling Maintenance on both systems. Mainfloor LefSide Carrier Straight A/C: Checked thermostat and air filters. Removed air filter. Checked blower motor amp draws. Checked all wiring. Inspected evap coil and blower wheel. Checked run cap. Made sure drain line was clear. Checked cfm and compressor amp draws. Checked dual cap. Compressor side weak, reading 24.1 out of 35. HO said she will call her home warranty. Cleaned condenser coil. Checked pressures. Found system 1 lbs low in ref. HO said she will call her HW. System needs 1 lbs of R22 and dual cap replaced to run great. Basement/Right Side Carrier Straight A/C: Checked thermostat and air filters. Checked blower motor amp draws. Checked all wiring. Inspected evap coil and blower wheel. Made sure drain line was clear. Checked cfm and compressor amp draws. Checked dual cap. Cleaned condenser coil
Trane gas furnace replaced blower motor and cycled system working at this time
Amanna heat pump checked system found compressor not starting due to bad dual run capacitor and replaced and cycled system working at this time
Rheem heat pump checked system found bad indoor TXV need to replace TXV
AMANNA a/C completed EPA cooling maintenance and cycled system working at this time
Goodman A/C replaced case coil amd cycled system working at this time
Goodman A/C replaced high pressure switch and cycled system working at this time
Goodman A/C with case coil checked system found to be low in refrigerate and preferred leak search and found leaking case coil need to replace coil
Rheem A/C replaced compressor bi flow drier and capacitor and recharged system with 5 lb R-22 and cycled system working at this time
Rheem A/C checked system found compressor not running due to being lock up need to replace compressor
Rheem air handler replaced blower motor and cycled system working at this time
Trane A/C checked system found compressor and CFM not running due to bad dual run capacitor and replaced with truck stock capacitor and cycled system working at this time
Goodman A/C replaced compressor and bi flow drier and capacitor and recharged system with 7 lb R-410 refrigerate and cycled system working at this time