Goodman heat pump checked system found to be running in ac mode due to bad reversing valve need to replace reversing valve
Goodman split heatpump replaced service valves and true suction line
Lennox gas furnace Cleaned dirty flame sensor
Goodman split heat pump. Replaced bad Evap coil with new and recharged the system
Incomplete 2 System worked DS Gas Pak System. HO Stated Gas furnace was not working. Found cracked heat exchanger and defective smart gas valve. Ordered parts. Will come back and replace parts as soon as they arrive.
Trane gas package unit heating tune up
Nordyne gas package unit. Replaced blower motor with correct blower motor
Payne split heat pump. Replaced faulty defrost board and coil sensor
Carrier split heat pump replace defrost board and defrost sensor
Payne split heat pump. Diagnosed bad defrost board and sensor
Carrier split heat pump found defrost board and defrost sensor bad