41638 Eastman Dr. Suite B
Murrieta, CA 92562
(888) 659-2665

Local Reviews
for anaheim, ca

Rated 4.6 out of 5 stars based on 5 customer reviews

Excellent Service!

Professional, knowledgeably, and honest.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very nice and very good service.

He patiently answered my questions and analyzed the problem and explained the solution, and the job he’s going to do.


Response from Cool Air Solutions:

Thank you so much for taking the time to leave an excellent rating. We really appreciate your business.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good and friendly service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service was great. Great price for the work

Had an issue with my air. Called cool air solutions and Luke responded. Absolutely wonderful. Fixed the issue an went over my new equipment with me til I understood.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Maintenance Service

Very satisfactory experience. Took his time to explain and was very knowledge on the produce.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for anaheim, ca

Alex R.

Alex R. Job Checkin

Combo maintenance


Christian G.

Christian G. Job Checkin

After having another estimate nearby, the client saw our promotion on a new AC unit and wanted more information. They were impressed that the same unit cost a lot less with Cool Air Solutions.


Brent L.

Brent L. Job Checkin

Client stated no heating -Flame would ignite for a split second and then shut off when power from thermostat -Furnace cuts out on high limit after 10 minutes -Temp rise is good -Return intake is 16” but gets reduced down into a very small return grill (14x20) -There is not enough airflow being drawn from house to properly cool the heat exchanger -A new return needs to be cut in to increase intake cfms


Brent L.

Brent L. Job Checkin

Door switch was installed, system is properly working<br> -Flame sensor cleaned<br> -Filter replaced<br> -Proper resistance for components <br> -Amps on motor is good


Brent L.

Brent L. Job Checkin

Technician arrived to perform furnace tune up -Filter is still clean -Flame sensor cleaned off -Electrical connections tightened -Heating elements working properly -Gas piping does not have sediment trap, was recommended -Blower motor is in rough condition, it is very dirty a drawing more power than it should -Blower motor replacement was also recommended -Clients are interested in repairs, would like me to follow up on February 3rd, after the holidays


Brent L.

Brent L. Job Checkin

Flue vent was in very bad condition and not safe to run the heater -New flue venting for furnace was installed, from bottom to top -Venting on roof was sealed properly to ensure no water leaks -Filter was extremely dirty, it was removed, tenant said he will replace it -Flame sensor was also cleaned off -Heating was ran for 30+ minutes, everything is working properly -House has good air flow


Evan V.

Evan V. Job Checkin

Performed a heating maintenance on a 2017 Goodman system. Cleaned and Adjust Burners. Check Combustion Air for Proper Venting. Examine the Heat Exchanger for Damage / Corrosion. Test Furnace Safety Controls. Inspect Gas Piping. Tighten Electrical Connections. Measure the Voltage and Amperage. Flush the Condensate Drains. Measure Tempurature Difference between Supply and Return Air. Vacuum Furnace Return Grille. Adjust Gas Pressure & Pilot. Clean in-place Blower Compartment. Inspect Blower Wheel for Proper Balance. Check the System's Static Pressures to Ensure Proper Airflow. Inspect Duct Connections for Air Leaks / Sizing / Insulation. Check all System Safety and Limit Switches. Clean Flame Sensor. Inspect Carbon Monoxide Detector. Check Thermostat for Proper Operation / Calibration. Filters where changed this visit.


Tony R.

Tony R. Job Checkin

During my twenty point heating inspection, I started with the thermostat. Giving a call for heating, and going to furnace to start maintenance. I checked out blower motor of any dirt or debris and it’s dirty. Both blower motors on each system should be deep cleaned. Dirt has built up on wheel fins. Motor controls are in good standing for both systems. Evaporator coil is starting to deteriorate on both systems. Starting to fall off during maintenance cleaning. One of the compressors for smoke shop is failing. Exceeds past 30 amps and decides to shut off after running for hour. I did last maintenance inspection, in beginning of year and this was same issue I addressed. Lots of amps are being used while running systems.


Luis M.

Luis M. Job Checkin

Upon arrival performed diagnostic, client has a bad thermostat. System kicks on when I jump at thermostat. Last set of fuses were blown. But passed technician said there was a ton of things that needed to be replaced. Client replaced there old thermostat because the screen wouldn’t kick on anymore. New thermostat was not programmed to heat pump. Programmed and system still didn’t run. Thermostat is not fully communicating to system. Bad thermostat. System is non operational. Also had disconnect in backwards so at first was never receiving power. Client is gonna return current thermostat . Please bill commercial owner


Luis M.

Luis M. Job Checkin

Upon arrival performed diagnostic, client has a bad thermostat. System kicks on when I jump at thermostat. Last set of fuses were blown. But passed technician said there was a ton of things that needed to be replaced. Client replaced there old thermostat because the screen wouldn’t kick on anymore. New thermostat was not programmed to heat pump. Programmed and system still didn’t run. Thermostat is not fully communicating to system. Bad thermostat. System is non operational. Also had disconnect in backwards so at first was never receiving power. Client is gonna return current thermostat . Please bill commercial owner


Luis M.

Luis M. Job Checkin

Upon arrival performed diagnostic, client has a bad thermostat. System kicks on when I jump at thermostat. Last set of fuses were blown. But passed technician said there was a ton of things that needed to be replaced. Client replaced there old thermostat because the screen wouldn’t kick on anymore. New thermostat was not programmed to heat pump. Programmed and system still didn’t run. Thermostat is not fully communicating to system. Bad thermostat. System is non operational. Also had disconnect in backwards so at first was never receiving power. Client is gonna return current thermostat . Please bill commercial owner


Luis M.

Luis M. Job Checkin

Upon arrival performed diagnostic, client has a bad thermostat. System kicks on when I jump at thermostat. Last set of fuses were blown. But passed technician said there was a ton of things that needed to be replaced. Client replaced there old thermostat because the screen wouldn’t kick on anymore. New thermostat was not programmed to heat pump. Programmed and system still didn’t run. Thermostat is not fully communicating to system. Bad thermostat. System is non operational. Also had disconnect in backwards so at first was never receiving power. Client is gonna return current thermostat . Please bill commercial owner


Tony R.

Tony R. Job Checkin

Arrived at Commercial building and started with unit on right side. Killed power to unit and started checking motor controls. System has a single motor control which was reading a little low, and the dual motor control that was reading low. I then checked out contactor and contacts were black and pitted. Contactor needs replacing too, blower motor (good), mother board (good), 24v (good), 240v (good). Coil cleaned and brushed to get dirt out of coil. Made sure pvc pipes were cleared and no back up drainage. Condenser fan motor is exceeding max amps, fan motor will fail. Condenser fan motor needing to be replaced. Compressor is exceeding max amps and will soon fail. Compressor using 20 amps and limit is 19.4. I recommended replacing whole package unit, because replacing all the parts internally will not fix compressor issue. Compressor is heart of system, system was low refrigerant of R22. There may be a leak in system, my pressures were really low on the low side. There is piping freezi


Michael P.

Michael P. Job Checkin

Installed PBA control board and programmed system in test mode. Installed outdoor surge protector.


Michael P.

Michael P. Job Checkin

Diagnosed defective board on outdoor Samsung system. Confirmed with tech support. Ordered replacement part with and will be installing with surge protector on the disconnect box.