Arrived on site to diagnose a no cooling a 2004 package unit. Spoke to client and he stated unit just he been starting to use unit and days before unit cooled good. Just recently he stated unit just did not cool. Only air flow was coming out. Got on to roof. Unit was running. Inspected electrical compartment. Starter was good. Circuit board was showing signs of wear but still operating. Checked pressure and found unit to be really low. Low side had only 11 pgsi. Unit is a r-22 unit and is no longer in production. Found unit to hold 13 and half pounds. Inspected condenser found oil spots and advised I would do a inspect of lines to see if leak is found. Opened u it up and expose line and Evaporator coil connections. Inspected current welds. Found liquid line to have a leak. Bubble tested and leak was found. Advised client would have to repair leak and then do a full charge up. As refrigerant is not included in repairs. Spoke over to tenant in home. He is aware of findings. Spoke to hom