Arrived on site to perform spring tune up on. 2 year old unit. Client stated no issues. Cycled unit on and operational. Washed condenser coil inside and out. Unit was really dirty. Checked electrical compartment. Primary starter is good. Secondary motor control is good as well. Fan motor is good and in range of amps. Compressor start up is good and in range. Run amps are good as well. Checked pressure and unit is holding a good charge and cooling hole good. Found no protection on either unit. Recommended protection as well to protect from electrical surges and power outages that can damage or even short out systems and components. Unit is cooling at 19 degrees. Cycled unit and went over how unit is running and conditions and recommendations. Clips aware and did hold off for now. Cycled unit and is operational upon departure. Client did renew maintenance plan yearly. Client Happy we came out today.