Kendall O.

Kendall O. Job Checkin

Performed furnace maintenance on 7 year old Carrier unit. Cleaned return grates. Inspected filter and found that it should last another 6 months. Temperature rise is within limits as well as the inducer and total unit electrical draw. Inspected flame sensor and found it to be clean. Tested resistance of hot surface igniter. Checked all electrical connections. Tested pressure switch. Tested all safety switches. Upon departure the system is operational.


Jimmy G.

Jimmy G. Job Checkin

Arrived on site to perform diagnostic on a 2010 Goodman unit. Spoke to client and he stated unit have not been cooling as good and house is really hot he been researching it online and stated he think unit just needs refrigerant. Cycled unit and inspected electrical compartment. Primary stated okay. Secondary motor control was out of range from compressor. Fan secondary was okay fan motor has been replaced in past. Checked preamp found unit very low. Advised client of findings and the issues as to why it’s not cooling. Advised him there is a leak present in the refrigeration cycle and is losing the refrigeration and is not cooling home down. Advised unit is almost flat. He stated in the 7 years he’s lived here has hasn’t had cooling issues just replaced a motor. Now unit is not cooling home and advised mini needs a charge up l. Client is aware of full condition about issues and leak. He stated due to how hot it is in home he is just trying to get unit cooling for now and then he


Freddy V.

Freddy V. Job Checkin

266 per month


Jimmy P.

Jimmy P. Job Checkin

Arrived on site and performed AC maintenance on condenser


Jimmy P.

Jimmy P. Job Checkin

Preformed furnace maintenance on 2018 carrier heater


Luis M.

Luis M. Job Checkin

Client did not need service


Luis M.

Luis M. Job Checkin

Client did not need service


Luis M.

Luis M. Job Checkin

Client did not need service


Luis M.

Luis M. Job Checkin

Client did not need service


Jimmy P.

Jimmy P. Job Checkin

Performed furnace diagnostic 2016 carrier heater. Upon my maintenance all components within the system checked out properly although found concerns regarding indoor air quality and filtration. Due to 1 inch filters only filtering out about 10 to 15% of the dust particles this has resulted in dust and debris buildup within the air mixing cabinet of the system. If filtration is upgraded This will not only increase the longevity of your system but the air quality within your home. Recommended that a 5 inch thick filter is installed on the HVAC system that has a one-year lifespan and 95% filtration efficiency. Additional upgrade To increase filtration to it’s maximum potential is adding in a whole house purification device that ionizes the air and sanitize all surfaces within the home While the system is operational in heating, cooling, fan Circulation mode. Upon departure system is fully operational and heating home


Jimmy P.

Jimmy P. Job Checkin

Performed furnace diagnostic 2016 carrier heater. Upon my maintenance all components within the system checked out properly although found concerns regarding indoor air quality and filtration. Due to 1 inch filters only filtering out about 10 to 15% of the dust particles this has resulted in dust and debris buildup within the air mixing cabinet of the system. If filtration is upgraded This will not only increase the longevity of your system but the air quality within your home. Recommended that a 5 inch thick filter is installed on the HVAC system that has a one-year lifespan and 95% filtration efficiency. Additional upgrade To increase filtration to it’s maximum potential is adding in a whole house purification device that ionizes the air and sanitize all surfaces within the home While the system is operational in heating, cooling, fan Circulation mode. Upon departure system is fully operational and heating home


Jimmy P.

Jimmy P. Job Checkin

Replaced condenser fan motor under warranty through carrier. System is fully operational and cooling upon departure


Jimmy P.

Jimmy P. Job Checkin

Performed AC diagnostic on 2016 carrier condensing unit. Upon my diagnostic I found that the condenser fan motor and compressor off when calling for cooling inside. Further investigation show that the secondary motor control was blown on the hermetic and fan side terminals. This is ultimately caused due to high amperage pull from the compressor and fan. Basically the equipment was working so hard on a hot day this component and gave out. Added a new secondary motor control system is fully operational and cooling house 5 ton Carrier- 1. Secondary motor control blown and not starting system. 2. Found condenser fan motor leaking oil from bearing 3. Compressor is pulling high amperage on start up 4. Disconnect had no surge protection or fuses inside of it Recommendations- 1. Replace secondary motor control with new one 2. Replacing condenser fan motor under warranty 3. Install compressor saver kit to reduce lock rotor amps and increase longevity of compressor