Arrived on site to perform spring tune up on 2 2004 Goodman units. Client son was home. Cycled both units and son stated one in has been down for 1 Month and wants it fixed for summer. Had to inspect bigger unit. Found start worn out. Secondary motor control is completely bad. Put a new one in to test if unit operational. Compressor turned off but fan motor did not. Advised fan is seized up. Unit would be needed parts replaced or as far as rebuilding unit to get it operational. Was not able to checked pressure but dose hold R-22. Washed condenser coil inside and out. Found starter worn out. Recommend replacing to prolong life. Secondary motor control is good as it has been replaced in past. Fan motor is leaking oil and is pulling max amps of 1.6 and advised motor can fail. Checked start up amps and compressor has high start up but in range recommend adding compressor booster kit due to age and hard start up to preserve compressor life. Run amps is pulling 9 amps and max at 16. Advise