Performed diagnostic on 10 year old Rheem system. Homeomer states that system was running and cooling last night. System ran all night before he noticed that thermostat had gone completely blank. Turned breakers off to shut the unit off. Upon arrival, flipped breakers back on to diagnose system. System immediately kicked into cool mode, and thermostat was blank. Checked for power at thermostat and it is recieving proper voltage. Thermostat has a bad display screen and has locked itself into cooling mode. Thermostat needs to get replaced. Also found that UV germicidal light in the coil is no longer working. It is recieving power but not turning on. Went over findings and recommendations with homeowner. With approval, went ahead and replaced with brand new thermostat and brand new UV light. Because the UV light was installed last year, it was still under parts warranty, labor was chargeable. Programmed thermostat accordingly and cycled through heating and cooling. System is programmed c