Arrived on site to perform combo tune up on a 2006 comfort maker system. Condenser located on side of home. Furnace and Evaporator coil located in attic. Washed condenser inside and out unit dirty. Checked electrical components and was good and unit was fully rebuilt. Fan motor is good and new. Primary and secondary motor controls are both good and new. Unit has compressor booster kit and good. Checked amp draws on compressor. Start ups are good and run amps are pulling 23 amps and Max rated at 25. Advised client how compressor is working and conditions and advisers her Compressor is on borrowed time and could fail at any time in future. System is cooling home at 23 degrees. No protection on unit. Cycled unit. Inspected indoor unit. Replaced filters client supplied. Blower assembly dirty and recommended cleaning assembly. Motor has been leaking oil out from past as dirty and oil are dried up on motor. Amp draws on motor are high as pulling 8.5 and Max rated at 12. Motor could fail at