41638 Eastman Dr. Suite B
Murrieta, CA 92562
(888) 659-2665

Job Locations
for lakeside, ca


Map of Lakeside CA
Jimmy G.

Jimmy G.


Job Checkin

Arrived on site to perform spring tune up on a 2018 lennox unit. Client stated no issues and is good. Cycled cooling. Washed condenser coil inside and out. Checked electrical. Primary stater is starting to show some wear from operation. Second motor control is good and In Range fan motor is good and free of oil and amps are in range. Checked start up and run on compressor. Start up was above max and recommended adding a compressor booster kit to help prevent hard start up. Run amps are good and in range. Checked pressure and unit is holding a good charge and cooling home. No protection on unit. Filter was replaced. Client supplied. Inspected indoor unit. Blower assembly and whee okay. Drain lines and drain pump are operational and draining. Unit is cooling hole at 19 degrees. All other safety switches are operational. No protection inside as well and highly recommended adding surge protectors to unit to protect from electrical surge and power outages that can damage or even short out