Performed AC/furnace maintenance A 1994 comfort maker system. This is the rental property of John Peterson. During the maintenance we also came across a few points of concerns that were addressed with John. AC- 1. Found the condenser fan motor had a oil leakage Coming from Lubricant seal of bearing. This can ultimately lead to the motor locking up or overheating due to lack of lubrication around bearing. 2. Duel secondary motor control has become weak and compressor side terminal. 3. Compressor pulling 10 A coming very close to the manufacture specification of 13 A 4. High voltage relay also contained high amount of pitting on contact points due to compressor using high amperage overtime this was eventually completely eat away at the brakes of the system. 5. System also contains R22 refrigerant which was completely phased out January 1, 2020 Furnace- 1. Inspected the heat exchanger and found no signs of cracks on eyelids. 2. Found an indoor blower motor was completely covered in du