41638 Eastman Dr. Suite B
Murrieta, CA 92562
(888) 659-2665

Job Locations
for san jacinto, ca


Map of San Jacinto CA
Jimmy G.

Jimmy G.


Job Checkin

Arrived on site to diagnose a no cooling 2004 system. Condenser located in back yard. Furnace and evaporator coil located in attic. Client stated he’s had issues before had another company come out and did some repairs and system still having issues and not opening at all. Upon arrival spoke over with owner had him cycled system to see how it’s operating and condenser did not turn on at all. Advised I would be checking both units. Checking electrical wiring, connections, circuit board, and components. Checked compressor and fan motor amp drawls. Checked refrigerant pressure. The summary of findings are as followed. Condenser 1. 2004 unit. 2. Condenser coil itself was in horrible condition as a dog has peed over it a lot in past coil is completely Deteriorated on bottom of one side of coil. 3. Condenser was found not operational As system had tripped breaker switch. 4. Found secondary motors Were wired in wrong for fan. Fan was replace in past and has its own single secondary mot