Arrived on site to perform fall tune up on a 2007 Rheem system located in back of house. Client stated no issues as she did repairs last years. Filter dirty and replaced As client supplied filter. Recommend replica every 3 months to reduce entering system. Ducting are old condition original to home. Blower assembly is good as it was cleaned in past. Motor is good as it was replaced. Secondary motor controls were both good as they were replaced. Primary motor control control is good and was replaced. Evaporator coil was good as it was cleaned and has slight dust accumulating due to areas surrounding home. Drain lines runs down floor. Temperature rise is good and in range. Found no protection equipped with this system. Recommend adding surge protectors to system to prevent damage fro electrical surges or power outages that can damage or short out components or even system. Cycled system to ensure system operating. Went over all findings and recommendations with client. Client is aware of