Nate and Patrick were efficient, polite and prompt. We would definitely recommend Cool Air Solutions based on their work.
The technician took extensive time to check the whole system, including the A/C unit, explaining what needs to be done in the future.
Performed AC maintenance and completed 20 points inspection
Performed AC maintenance on Lennox system
Heating maintenance on Lennox furnace performed 20 point inspection
Performed heating maintenance on 4 year old Lennox unit. Checked filters and found them in good condition, Mr. Martian replaces his own filters. Temperature rise is within limits. Inspected blower compartment and found blower wheel to be clean and balanced. Inspected flame sensor and found it to be clean. Checked all electrical connections. Tested resistance of hot surface igniter. Measured external static pressure and found it to be near mfg’s recommendation. Flushed condensate drain with water. All electrical amp draws are within tolerances. Prior to departure I ensured the furnace was operating normally after my maintenance inspection.
Performed heating maintenance on 4 year old Comfort Pro/Goodman unit. Resecured ‘r’ wire on the low voltage bus on the furnace control board. Checked all safety switches. Cleaned flame sensor. Inspected blower compartment and found blower wheel to be clean and balanced. Installed new MERV 16 filter. Flushed condensate drain with water. Temperature rise is within limits. All electrical amp draws are within limits. Dina let me know that there is very little air flow out of one of the registers in the family room upstairs. I inspected the duct work that I had access to to see if I could determine the problem. I removed a panduit tie that was restricting a duct but that didn’t resolve the problem. I put my inspection camera about 10’ down that duct run and found a lot of rat droppings and as though a rodent was eating away at the duct, it was clogged up with a lot of insulation. I told Dina that I would see if we have a camera that can reach further in the duct before
Arrived on site to to perform heating tune up on a 5 year old lennox.
Arrived on site and performed AC maintenance on 2016 Lenox unit
Upon arrival performed Maintenance on heating system. Found filter to be dirty, client buys his own online. Recommended adding surge protection to keep circuit boards and electrical protected. Signed client up with maintenance plan. Cleaned flame sensors. Temp splits in range. Static pressures good. Dusted off all electrical components. Ducting in great condition. Thermostat in working order. Amperages are in range. System is operational upon departure.
Upon arrival performed Maintenance on heating system. Found filter to be dirty, client buys his own online. Recommended adding surge protection to keep circuit boards and electrical protected. Signed client up with maintenance plan. Cleaned flame sensors. Temp splits in range. Static pressures good. Dusted off all electrical components. Ducting in great condition. Thermostat in working order. Amperages are in range. System is operational upon departure.
Upon arrival performed Maintenance on heating system. Found filter to be dirty, client buys his own online. Recommended adding surge protection to keep circuit boards and electrical protected. Signed client up with maintenance plan. Cleaned flame sensors. Temp splits in range. Static pressures good. Dusted off all electrical components. Ducting in great condition. Thermostat in working order. Amperages are in range. System is operational upon departure.
Upon arrival performed Maintenance on heating system. Found filter to be dirty, client buys his own online. Recommended adding surge protection to keep circuit boards and electrical protected. Signed client up with maintenance plan. Cleaned flame sensors. Temp splits in range. Static pressures good. Dusted off all electrical components. Ducting in great condition. Thermostat in working order. Amperages are in range. System is operational upon departure.
Performed routine spring maintenance on Lennox condenser in Spring Valley. Tessa verify correct operation of system, recommend staying on maintenance plan due to the condenser being extremely dirty at time of visit. This is the first of two visits with the maintenance plan they will be up for renewal on the next visit. Clean entire outdoor unit back to factory fresh, system is running correctly at this time.
Replaced thermostat with NestPro and set up homeowner WiFi network
Upon arrival found thermostat to be faulty. Does not engage for heating, replaced under warranty and installed a honey well T6 pro WiFi, replaced filter. System is operational upon departure.