41638 Eastman Dr. Suite B
Murrieta, CA 92562
(888) 659-2665

Job Locations
for valley center, ca


Map of Valley Center CA
Shane P.

Shane P.


Job Checkin

Heating Maintenances Performed Upon arrival systems are working and operational. I began my maintenance in the attic by performing a duct leakage inspection. I then proceeded to the air handler units, split attic access. I checked and tightened electrical connections. I inspected the heating components for proper operation and wear. Condensates lines were inspected for proper drainage. Static pressures and temperature splits were taken. Filters have been changed at this time. Blower housing and wheel was inspected for balance and dust build up. Air supply was measured. Inspected safety switches as well as inspected home for fire and carbon monoxide detectors. I then proceeded to the outdoor units, I broke them down and cleaned them by flushing the coil of debris and dirt. I checked refrigerant pressures and measured amp draws. I checked for wear and tight connections on the units. Upon inspection of the indoor air handler units I found there to be no form of electrical protection on