Job Checkin

Arrived on site to perform spring tune on a 2013 Goodman unit. Condenser located in back. Furnace and Evaporator coil located in outdoor closet. Cycled unit. Washed condenser coil inside and out. Checked electrical compartment. Primary starter was a bit worn out due to age and normal operation. Secondary motor control was good in range. Fan motor was good and amp were in range. Checked pressure and are good and cooling hole at 22 degrees. Inspected indoor unit. Furnace really dusty due to being in a Outdoor closet and where home is surrounded by. Found 2 flyer used and advised that is not good and should only have one filter to prevent airflow restriction. Left one filter in furnace and was replaced. Blower assembly is dirty. Motor is good and secondary control as well. Drain line has no safety overflow switches. System is cooling at 22 degrees. Cycled system to ensure system operating. Went over all findings with client. Client is aware of how system is running and it’s condition. C