3129 Swetzer Rd. # G
Loomis, CA 95650
916-577-5020

Local Reviews
for folsom, ca

Rated 4.9 out of 5 stars based on 34 customer reviews

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Brandon did a great job! He explained everything very well! Thank you for your service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Scott is such a hard worker and very efficient at explaining things to us..he is kind and courteous and polite. ..we really like this young man..thanks for coming today..

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

we were pleased with scott.. he knew what he was doing and the job. got done fast. i would use him again. thank you for a good job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Ken provided a straight forward quote, answered all questions and delivered on time. We can finally enjoy our home comfortably whether it's very hot or cold outside

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Bradford receives: Excellent!!! Over & beyond!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Knowledgeable Friendly and direct to points of concern.

Pricing was not in my budget range, but I appreciated the quote.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Knowledgeable, reliable, fast service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for folsom, ca

Scott P.

Scott P. Job Checkin

Member would like to set appointment for installation of ADA toilet. please call her when available to set appointment Removal of Standard Toilet, Install of ADA Unit Removal of old toilet and possible supply line replacement Member would like Follow up call in regards to shut off gate valve for Watermain and hose bibs surrounding home x2


michael E.

michael E. Job Checkin

We will install (1) 3 Ton Trane model XR17 Condenser paired with a XV80 furnace. ARI Reference Number 8934588 to ensure energy efficiency rating. Unit will achieve a energy rating of 17SEER/13EER Two Stage Cool paired with a 80% Two Stage Heat with True Variable Speed Blower Split System. Installation of Equipment will need (1)supply plenum and (1) return plenum, new drain pan with risers. New gas flex with gas cock will be installed. New condenser pad for outside condenser, new electrical disconnect and electrical whip will be installed. Nest thermostat to be installed. Reseal all ductwork per Title 24 airflow requirements and tested to allowed leakage. Install IWave Ion whole Home air scrubber air filtration. We will install (1) 3 Ton Trane model XL16c gas/electric package unit. ARI Number 7795515 reference number to ensure energy efficiency rating. Unit will achieve a energy rating of 16.6 SEER/12EER Two Stage Heat/2 Stage Cool with True Variable Speed Blower. Crane will be needed


Jeremy F.

Jeremy F. Job Checkin

Customer has new flooring being installed and they noticed dry rot opposite wall of the hall bathroom. Flushed the toilet multiple times and determined there is not an existing leak at this time. One the flooring is done we will be coming back to install all new toilets and recommend new angle-stops when the toilets are installed. Customer will contact us when they are done with the flooring, today just provided a piece of mind inspection.


Brandon B.

Brandon B. Job Checkin

Replaced motor, double shaft hydronics blower motor in ceiling. Found unit not operating partially seized blower motor, replaced and tested system. system working at this time. Tenant would like a new tstat, one easier to use, let managers know.


Brandon B.

Brandon B. Job Checkin

Replaced motor, double shaft hydronics blower motor in ceiling. Found unit not operating partially seized blower motor, replaced and tested system. system working at this time. Tenant would like a new tstat, one easier to use, let managers know.


Brandon B.

Brandon B. Job Checkin

Replaced motor, double shaft hydronics blower motor in ceiling. Found unit not operating partially seized blower motor, replaced and tested system. system working at this time. Tenant would like a new tstat, one easier to use, let managers know.


Jeremy F.

Jeremy F. Job Checkin

Customer has a broken gate valve on his irrigation shut off, further diagnosis revealed the main gate for the home is also leaking. As an added benefit I checked the pressure after the prv valve and its at 90 to 95 psi which is dangerous water pressure coming into the home. Provided estimates for all the issues, and the customer will contact us when he decides what he wants to do.


Jeremy F.

Jeremy F. Job Checkin

Customer has a sewer smell coming from his hallway bathroom, all the sewers are very active and p-traps are full. Further diagnosis revealed a broken pedestal sink drain and a toilet that has a broken wax ring and no silicone. Presented the estimate to the customer with the Crystal Blue pricing included, emailed the estimate and the customer will contact us when he is ready to get this problem fixed.


Chanse J.

Chanse J. Job Checkin

Found 80 gallon A.O. Smith electric water heater with a failed upper thermostat and possibly lower thermostat. Unable to diagnose lower element due to upper thermostat not working. Recommend installing new upper thermostat and potentially lower thermostat and element. Owners declined to do the repair at this time


Scott P.

Scott P. Job Checkin

Performed diagnostic on hydronics unit. Heater not working no power. Found unit turned off. Turned furnace on after testing air handler looks ok. Tested hot water flowing, and over 100 degrees, transformer working, high and low voltage ok. Checked air out of vents 100 degrees in vent. System working fan running in heat mode, sounds like Blower motor making squealing noise. Blower motor going bad.


Kenneth H.

Kenneth H. Job Checkin

We will install (1) 3 Ton Trane model XR17 Condenser paired with a XV80 furnace. ARI Reference Number 8934588 to ensure energy efficiency rating. Unit will achieve a energy rating of 17SEER/13EER Two Stage Cool paired with a 80% Two Stage Heat with True Variable Speed Blower Split System. Installation of Equipment will need (1)supply plenum and (1) return plenum, new drain pan with risers. New gas flex with gas cock will be installed. New condenser pad for outside condenser, new electrical disconnect and electrical whip will be installed. Nest thermostat to be installed. Reseal all ductwork per Title 24 airflow requirements and tested to allowed leakage. Install IWave Ion whole Home air scrubber air filtration. We will install (1) 3 Ton Trane model XL16c gas/electric package unit. ARI Number 7795515 reference number to ensure energy efficiency rating. Unit will achieve a energy rating of 16.6 SEER/12EER Two Stage Heat/2 Stage Cool with True Variable Speed Blower. Crane will be needed


Chanse J.

Chanse J. Job Checkin

Recommend installed new 50 gallon Bradford white gas Water heater with gas valve, flex line, expansion tank, supply lines, reattach the temperature relief line, removal and disposal of the old water I am going to schedule to return tomorrow afternoon to replace the venting current venting was in a worse shape than I had thought. Returned and replaced venting , Unit is properly working. Showed homeowner how to operate equipment by turning the temperature up and down. Homeowner is satisfied with the work that was completed. Homeowner declined club membership


Scott P.

Scott P. Job Checkin

Performed furnace diagnostic Folsom. Found one terminal missing wire nut, added to system. Tested system couldn’t still get system to work. Found that thermostat wasn’t sending signal correctly. When I jumpered the w wire it would work. Then installed there tstat. System turned right on. Maintenance there to see system operational at this time.


Kenneth H.

Kenneth H. Job Checkin

Performed annual heating maintenance Folsom. Split heat pump system, air handler from 1985, heat pump from 2007. Air handler in attic, with new silver ducts, new drain pan. Tested system, found contactor burning and pitted. Recommend replacement of part. Also hard start kit it low, it’s capacitor should be between 216-240@150. Blower capacitor new. Not very efficient, due to age of system. Lineset insulation is falling apart outside. Filters are due to be changed. 14-25-1 and 20-25-1. Gave unit a good bath, rinsing coils to keep unit running as good as possible. With future repairs coming in around 500$ want to watch how much money you put into a system of this age. Newer equipment is much more efficient.


Scott P.

Scott P. Job Checkin

Performed diagnostic found system off, not working, tested electrical all ok, then tested system, system caught fire. System is off need new motor. Looking for replacement motor will call tomorrow with more info. Replaced motor, then found system not working, still has possible small water leak inside unit. But isn’t leaking right now. Found hot water pump not wired up, so rewired the pump and tested system. System on and working right now. Tested system multiple times.