3129 Swetzer Rd. # G
Loomis, CA 95650
916-577-5020

Local Reviews
for loomis, ca

Rated 4.9 out of 5 stars based on 128 customer reviews

Great service

He really checked throughly and suggested a good deal.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job

knowledgeable and fun to talk to.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job

Keaton explained the issues and options well.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very professional and courteous!

Crystal Blue has never disappointed me. Mike was able to fix an issue I had with getting hot water when another big name company could not fix it in several attempts. I highly recommend this great company.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great ! Thanks

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

H2O heater changeout by Taylor Irik was performed promptly and with attention to detail (craftsmanship!). Taylor was courteous and professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great information

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Always a great experience with service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Such a nice young man and very knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for loomis, ca

Scott P.

Scott P. Job Checkin

Performed ac diagnostic, system working at this time. Wasn’t working last week, checked dual capacitor ok. Contactor working at this time. Unit cycling on and off on its own. Outside condenser coils dirty, gave unit a bath. Tested refrigerant pressures ok. Need to check filter attic. Changed 4 in filter in attic. Tight fit. 20-25-4... let system run to see if it would do anything different ran just fine for me today. They said couldn’t get from zone to work. Working now. 3 zone system working ok at this time. No amps installed. Temp hits then purge cycle then back on again system running at this time. If problem consists will need to be here while it’s happening to determine cause Resigning back up on membership, maintenance includes ac tune ups, furnace tune ups, and plumbing inspection with tankless water heater flush.


Samuel T.

Samuel T. Job Checkin

- Disconnect electrical power to existing garbage disposal - Disconnect drain lines from garbage disposal to install new - Provide new STANDARD garbage disposal for installation - Modify electrical to remove wiring that does not meet minimum safety stand - Install new outlet with built-in electrical breaker for safety underneath sink for easy garbage disposal disconnect - Replace double switch at countertop with new double switch - Modified drain lines to match dimensions of new garbage disposal - Start up sequence and fine-tuning included 3 YEAR WARRANTY Note water leak under sink customer aware of leak and would like to watch leak to see if it gets worse or gets better will call us if it gets worse to make repairs


Scott P.

Scott P. Job Checkin

Performed swamp cooler diagnostic loomis. Found float to high and water overflowing unit left side. Adjusted float, drained unit, tested system. System not leaking as bad. Still a drop here and there. Pads don’t cover opening fully. Belt looks ok. Unit operational at this time. Top of the unit is level, bottom leans to the left upper corner, that’s where it’s leaking from. System getting older, starting to rust in many places, float adjustment only temporary fix, either going to need to rebuild unit, or eventually will want to think about replacement.


Scott P.

Scott P. Job Checkin

Went over options over the phone for his install of 2 x split systems with xl16 units outside furnaces and coils in attic with new plenums. cash price 21500 due at completion of job.


Scott P.

Scott P. Job Checkin

Performed ac diagnostic, found system off with fan on. Turned system on and fan to auto. Tested system on roof all 3 capacitors in range and working, Contactor working. Ran system to see if cooling. Cooling well, 20 degree temp split. Turned thermostat down to 80, and switched fan to auto from on. Due to age of equipment, might want to look into replacement options.


Jeremy F.

Jeremy F. Job Checkin

Customer has a shower valve that is not mixing hot and cold water like it is supposed to, I recommend a new shower cartridge considering it is 20 years old. Customer agreed and we will order the cartridge and contact the customer when we can return and install the new cartridge.


Scott P.

Scott P. Job Checkin

Performed ac diagnostic loomis, found control board failed. See pictures. Need to order part and see availability. Coming back later today to install


Samuel T.

Samuel T. Job Checkin

- Shut water off to whole house - Rebuild shower includeds shower valve parts inside wall, handles, provided by customer -Shower valve rebuilt and fully functional - Shower valve to be trimmed out but will require additional modifications customer responsible for completion of project - Tested for water leaks with building pressure CASH PRICE


Samuel T.

Samuel T. Job Checkin

Collect the down payment and scheduled work for Monday morning will install new garbage disposal and make repairs to electrical by installing a GFCI outlet underneath the sink


Scott P.

Scott P. Job Checkin

Performed ac diagnostic master bedroom unit, found seized outdoor fan motor. Installed a new condenser fan motor, tested system. System cooling at this time.


Keaton R.

Keaton R. Job Checkin

Came out for diagnostic in Loomis. Unit is a rooftop Goodman package unit. Checked all around unit and looks okay no damage to unit. Tested unit before diagnostic to ensure unit was running. Checked all electrical and is okay. Found that unit has extremely low refrigerant levels and that is why it is not cooling well.


Michael E.

Michael E. Job Checkin

Loomis California performed AC diagnostic found compressor with tripped main breaker found electrical wiring at main breaker loose tightened electrical wiring at breaker inspected rest of system found electrical tight at service disconnect, found electrical connections tight inside of unit, performed electrical test on unit found electrical test to be showing a caution which is indicate a possible short. tested compressor independently found compressor windings causing issue in conjunction with loose electrical wiring caused the breaker to trip. Compressor issue will most likely cause compressor to burn out completely recommend replacement of system customers doing a remodel towards the end of the year will most likely have the systems replaced then. Will need to perform AC maintenances within 2 to 3 weeks per agreement with customer


Keaton R.

Keaton R. Job Checkin

Came out for diagnostic, tech couldn’t diagnose where issue is as to why unit isn’t turning on. Checked all electrical connections and tested for proper voltage from disconnect. Has 240v at contactor and contactor is working properly. Checked capacitor and is in range so that isn’t the issue. Thermostat is working properly. Will send out a Senior Tech tomorrow Wednesday 05/27 between 12-4pm. Will collect for diagnostic when senior tech finds issue.


Jeremy F.

Jeremy F. Job Checkin

Customer has a leak at the drain down spout of the water heater, he hand tightened a cap but it is still leaking. Customer denied any work at this time and wants a recommendation so that he can have his home warranty change out the water heater. The water heater is over 20 years old and severely not up to code, the damage the water has done to the very minimal stand is alarming. In my recommendation the water heater needs to be replaced before it causes serious damage to the home. Provided estimates to the customer and emailed my recommendation as well.


Grayson  C.

Grayson C. Job Checkin

Customer has a garbage disposal that does not work and a Fossett that has a tendency of turning itself back on due to a broken cartridge and broken handle. The customer wants to call her home warranty and see if they will reimburse her for the work. She will call the office to reschedule.