3129 Swetzer Rd. # G
Loomis, CA 95650
916-577-5020

Local Reviews
for meadow vista, ca

Rated 5.0 out of 5 stars based on 4 customer reviews

Great experience

Great customer service and professional work completed. I have used them on multiple occasions and highly recommend.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional and courteous

Was able to schedule same day service. Very profressional, clean and courteous. Gave great recommendations and knew his stuff. Much appreciated!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt Service!

Kevin was both timely and professional with the replacement of our dead garbage disposal.

  • Overall Experience
  • Quality
  • Price
  • Convenience

A job well done

I feel like I've found a plumbing company I can trust, and would not hesitate to call them again should the need arise. Sean was knowledgeable and efficient.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for meadow vista, ca

Jeremy F.

Jeremy F. Job Checkin

Performed a whole home plumbing inspection, during the inspection I found that the water pressure is at a dangerous 140 psi. Highly recommend new prv be installed and ball valve at the water main, the toilet in the master bathroom rocks and the tank to bowl bolts are almost completely rusted out and could use a new flush valve as well. The water heater located in the garage has single wall venting that is touching the wood roof, single wall needs a 6 inch clearance from combustibles where double wall only needs one inch clearance so the venting need to be changed and the t&p needs to drain into the garage sink at least if not exiting the home. The master bathroom shower valve will only stop if you hit the sweet spot, so it needs to have the cartridge rebuilt. Provided all the estimates to protect the customers home from any unwanted damage or emergency that we can see at this time, she will contact us when she decides to have us fix these issues.


Jeremy F.

Jeremy F. Job Checkin

Customer has a water heater that went out and will not re-light, upon diagnosis the water heater started up just fine. I waited for over 15 minutes and the water heater stayed on with no issues at this time.


Scott P.

Scott P. Job Checkin

Performed furnace diagnostic, heat only furnace, with new tstat. Found blown low voltage fuse. And loose wire connection inside unit. Replaced 3 amp fuse and tightened g wire. Then tested system. System runs need to to keep an eye on the blower capacitor, and inducer motor sounds rough. Also with age of equipment want to watch how much money we are putting into system, Regular maintenance of system System, furnace only in closet, swamp cooler on roof. And plumbing. Plumbing inspection would like soon. Inbetween tenants at this time.


Scott P.

Scott P. Job Checkin

Standing inspection with fire Marshal. Pressurized line from propane tank to generator. 15lbs for 15 mins. Line held fine. Lost no pressure. (Line actually was charged for over an hour with no movement on gauge.) Fire Marshal came out and signed off on inspection. Backfilled trench and hooked up gas line to generator. The county of placer also showed up and signed off on job as well. While county inspector was on the job, the inspector stated that he was going to sign off on the yard gas but to get a complete sign off on the job the contractor for the electricians needs to call back the fire inspector and the county for complete sign off. Plumbing contractor part of job is signed off and we are good to go.


Samuel T.

Samuel T. Job Checkin

Pricing options given to customer Customer declined services since need to review options with her husband Customer refused signatures of any kind


Samuel T.

Samuel T. Job Checkin

- Drain plug found in line and didn’t need cable snake - Test by running water


Chanse J.

Chanse J. Job Checkin

Lifted gas line dug underneath to the depth of 21 inches lower gas line back down covered sections make sure it was 18 inches deep and rotated 90 above ground towards the generator. The line is going to need to be pressure tested and inspected by the city, after inspection homeowner is going to call her propane company and have them add a secondary regulator. After the regulators installed we will need to return and hook the gas line up


Brandon B.

Brandon B. Job Checkin

Locate leach lines for septic system per city request. Main sewer line and septic system has been located at distance of 30+ feet from electrical line supplying power for new whole house generator at closest point. System has been located and marked in white paint for physical reference, also included pictures with detailed information in event that marks get washed away.


Brandon B.

Brandon B. Job Checkin

Locate leach lines for septic system per city request. Main sewer line and septic system has been located at distance of 30+ feet from electrical line supplying power for new whole house generator at closest point. System has been located and marked in white paint for physical reference, also included pictures with detailed information in event that marks get washed away.


Brandon B.

Brandon B. Job Checkin

Locate leach lines for septic system per city request. Main sewer line and septic system has been located at distance of 30+ feet from electrical line supplying power for new whole house generator at closest point. System has been located and marked in white paint for physical reference, also included pictures with detailed information in event that marks get washed away.


Brandon B.

Brandon B. Job Checkin

Customer has purchased 16 kw 272,000 btu Generac generator from another company and needs to have a quote to have gas line installed. Unit is 25 feet from propane tank and needs gas line to be ran under ground. Will dig trench to depth of 18 inches per code from propane tank to within one foot of generator. Gas line will be flexible poly direct burial pipe to meet code and unit requirements. Quote has been adjusted per customer request, and now includes fee for pulling a permit for gas line work to be inspected by county/city. Returned on Wednesday, December 4 and Thursday, December 5 to install inch and a quarter black iron gas line to supply new generator. Wednesday Dug trench 18 inches deep and total length of 25 feet. Pipe is wrapped in 20 mil tape per code for gas pipe buried in ground, and painted exposed pipe above ground per code. Once gas line was installed did pressure test on new line, line is holding pressure. Installed gas flex and pipe to generator, generator has de


Brandon B.

Brandon B. Job Checkin

Customer has purchased 16 kw 272,000 btu Generac generator from another company and needs to have a quote to have gas line installed. Unit is 25 feet from propane tank and needs gas line to be ran under ground. Will dig trench to depth of 18 inches per code from propane tank to within one foot of generator. Gas line will be flexible poly direct burial pipe to meet code and unit requirements. Quote has been adjusted per customer request, and now includes fee for pulling a permit for gas line work to be inspected by county/city. Returned on Wednesday, December 4 and Thursday, December 5 to install inch and a quarter black iron gas line to supply new generator. Wednesday Dug trench 18 inches deep and total length of 25 feet. Pipe is wrapped in 20 mil tape per code for gas pipe buried in ground, and painted exposed pipe above ground per code. Once gas line was installed did pressure test on new line, line is holding pressure. Installed gas flex and pipe to generator, generator has de


Brandon B.

Brandon B. Job Checkin

Customer has purchased 16 kw 272,000 btu Generac generator from another company and needs to have a quote to have gas line installed. Unit is 25 feet from propane tank and needs gas line to be ran under ground. Will dig trench to depth of 18 inches per code from propane tank to within one foot of generator. Gas line will be flexible poly direct burial pipe to meet code and unit requirements. Quote has been adjusted per customer request, and now includes fee for pulling a permit for gas line work to be inspected by county/city. Returned on Wednesday, December 4 and Thursday, December 5 to install inch and a quarter black iron gas line to supply new generator. Wednesday Dug trench 18 inches deep and total length of 25 feet. Pipe is wrapped in 20 mil tape per code for gas pipe buried in ground, and painted exposed pipe above ground per code. Once gas line was installed did pressure test on new line, line is holding pressure. Installed gas flex and pipe to generator, generator has de


Brandon B.

Brandon B. Job Checkin

Customer requested quote to run gas line for newly purchased whole house generator purchased from another company. Upon arrival looked at generator to see what gas requirements where needed by manufacturer recommendation and discussed options and concerns with customer. Found that a permit for generator to be installed was not discussed about with customer and informed her that one needed to be pulled for her piece of mind and safety. Customer accepted quote presented by Crystal Blue , but asked that we include price to pull a permit for work to be performed. Quote now includes a total price with permit as requested.


Brandon B.

Brandon B. Job Checkin

Customer requested quote to run gas line for newly purchased whole house generator purchased from another company. Upon arrival looked at generator to see what gas requirements where needed by manufacturer recommendation and discussed options and concerns with customer. Found that a permit for generator to be installed was not discussed about with customer and informed her that one needed to be pulled for her piece of mind and safety. Customer accepted quote presented by Crystal Blue , but asked that we include price to pull a permit for work to be performed. Quote now includes a total price with permit as requested.