3129 Swetzer Rd. # G
Loomis, CA 95650
916-577-5020

Local Reviews
for placerville, ca

Rated 5.0 out of 5 stars based on 1 customer reviews

Great!

our new water heater is so sweet, works great,very quite. we would like to thank tom again. he worked extra hard to make it happen for us. warm regards

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for placerville, ca

Brandon B.

Brandon B. Job Checkin

Customer Gabe requested an inspection and report of 4 individual roof top storm drain lines before having roof work done on Placerville Post office. Storm drains are located in he 4 outer most corners of building and are made of cast iron. 2 of the storm drains, drain directly onto street, 1 into garden area, and 1 into storm drain catch basin in post office parking lot. All 4 roof top drains have vents within 8 inches of drains that are not covered but raised above roof line approximately 1.5 inches. Vents and drains are clear at this time with minimal leaf debris contained inside. All drains appear to be in good condition with no separation or major scaling(rotting/rust). Camera inspection of 4 roof top storm drain lines. Customer requested report before having roof work done


Brandon B.

Brandon B. Job Checkin

Customer Gabe requested an inspection and report of 4 individual roof top storm drain lines before having roof work done on Placerville Post office. Storm drains are located in he 4 outer most corners of building and are made of cast iron. 2 of the storm drains, drain directly onto street, 1 into garden area, and 1 into storm drain catch basin in post office parking lot. All 4 roof top drains have vents within 8 inches of drains that are not covered but raised above roof line approximately 1.5 inches. Vents and drains are clear at this time with minimal leaf debris contained inside. All drains appear to be in good condition with no separation or major scaling(rotting/rust). Camera inspection of 4 roof top storm drain lines. Customer requested report before having roof work done


Brandon B.

Brandon B. Job Checkin

Customer Gabe requested an inspection and report of 4 individual roof top storm drain lines before having roof work done on Placerville Post office. Storm drains are located in he 4 outer most corners of building and are made of cast iron. 2 of the storm drains, drain directly onto street, 1 into garden area, and 1 into storm drain catch basin in post office parking lot. All 4 roof top drains have vents within 8 inches of drains that are not covered but raised above roof line approximately 1.5 inches. Vents and drains are clear at this time with minimal leaf debris contained inside. All drains appear to be in good condition with no separation or major scaling(rotting/rust). Camera inspection of 4 roof top storm drain lines. Customer requested report before having roof work done


Sean D.

Sean D. Job Checkin

3/4 copper water main has a leak at the house customer has it dug up will replace up to two feet will use copper pipe and two couplings.


Sean D.

Sean D. Job Checkin

No water at faucet checked supply there’s water faucet needs to be replaced also leak at waste arm need new trap adapter. P trap . Replaced faucet have good water presure hot and cold no leak at waste connections


Tom D.

Tom D. Job Checkin

Top complete checked all faucets for hot water everything okay no leaks. Customer inspect all approved. Customer understands they are in charge of permit if they so choose to pull one. Price includes Parts labor when your warranty leaks labor.