3129 Swetzer Rd. # G
Loomis, CA 95650
916-577-5020

Local Reviews
for rocklin, ca

Rated 4.8 out of 5 stars based on 65 customer reviews

Great Service

The service was great. The guys went out of their way to make life easier for me.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

This is the second time we have used Sam with Crystal Blue plumbing. Again, he was prompt and courteous and took the time to fully explain the situation. Without a doubt, we will use them again.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great representative

Great presentation, lots of information. The presentation for new venting was not totally explained, however, when I read the "invoice proposal" I recognized direct vent. Direct vent was never mentioned.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!!

Attention to detail was awesome. Finished results better than I could imagine. THANKS

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Very good couldn't be happier

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Our experience was excellent. The technicians were timely- calling when they said they would and the service was fantastic. Thank you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Exceptional Amazing Service!!

I Highly Recommend The Exceptional Customer Service that’s provided by a Quality Team of Experts..

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Jeremy was very polite and friendly concerning the estimate for the new hot water tank and member ship plan and willing to answer any questions my husband and I had. Tanks Jeremy

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and great company to work with

Scott Petty definitely very knowledgeable and personable as well. Great experience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for rocklin, ca

Jeremy F.

Jeremy F. Job Checkin

Upon arrival customer’s woman’s restroom has two toilets that are in need of repair. The right side toilet the fill valve and flapper needs to be replaced and the tank to bowl wiggles when touched. On the left side toilet it is very loud from the fill valve and gaskets deteriorating. Both toilet are of the same age and in order to avoid any issue’s in the future minor and/or major rebuild of both toilets recommended. The kitchen sink has a backup of water when the water is ran. In order to snake would need to remove the waste assembly to gain access to run the snake. A snake is recommended. Customer will contact us after they approval to do the work.


Scott P.

Scott P. Job Checkin

Performed commercial furnace diagnostic Rocklin. Hanging sterling heater. Found unit fan running but nothing else. No pilot or burners. Tested system found tripped high limit switch, reset and system turned on. Fan doesn’t sound good, and is hot to the touch. Need to replace motor. Emailed client tentative estimate, won’t know actual price and availability on motor until I hear from supply house


Scott P.

Scott P. Job Checkin

Found system not working correctly. Replaced heat sensor, appears to be burnt and wires not long enough. So lengthened wires. Tested system multiple times working for now.


Jeremy F.

Jeremy F. Job Checkin

Met with maintenance manager, unit 103 has a leaking water heater from the bottom. Customer supplied the water heater, during installation we had to rework the copper and venting to meet the new water heater sizing. Installed new gas valve and flex line, tightened the straps down. T&P is not the same and could not be re-attached to the piping coming out of the wall, customer is responsible for pulling a permit which was requested by the maintenance manager Frank. Turned the water on with no leaks, turned the gas on and the water heater is working perfectly.


Scott P.

Scott P. Job Checkin

Performed zoning diagnostic, carrier split zoned system attic. Tested zoning. First tested downstairs tstat on, and tested to see if zoning was working. Next turned on upstairs heating. Zone damper opened up. Next tested system by turning off downstairs. So just upstairs is running. Zoning is working as it is suppose to be working at this time. See pictures. System does have some blow by, airflow making its way thru system even if zone is shut, that’s normal. Also found upstairs tstat fan mode set to circulate. Switched it to auto, to stop it from turning on upstairs on its own a few times an hr. Hvac diagnostic


Samuel T.

Samuel T. Job Checkin

Visit with manager about possible options for repairs


Jeremy F.

Jeremy F. Job Checkin

Customer has a 13 year old 75 gallon water heater that is not working correctly, upon diagnosis there is a recirculation pump attached to the unit. The hot side connection is about to snap, and the tank is leaking on the inside of the water heater and starting to fill up the drip pan. Highly recommend this unit is replaced before it causes water damage to the home and the recirculation pump should be changed out as well. Customer had to leave and so i emailed the estimates to her and they will contact us when they decide to have us do the work.


Jeremy F.

Jeremy F. Job Checkin

Bradford White 50 Gallon natural gas with new expansion tank installed to be brought up to code. New water supply lines, straps. Per Ken. Removed the old water heater, installed the new water heater bringing it up to code. Turned the water on with no leaks, turned the gas on and the water heater worked perfectly.


Brandon B.

Brandon B. Job Checkin

Entry way lavy sink repair. Customer has tried multiple times to repair pop up assembly for entry way bathroom but keeps leaking or breaking. Pop up assembly was not assembled correctly, removed and reassembled. Tested for operation and leaks, no more issues at this time.


Brandon B.

Brandon B. Job Checkin

Entry way lavy sink repair. Customer has tried multiple times to repair pop up assembly for entry way bathroom but keeps leaking or breaking. Pop up assembly was not assembled correctly, removed and reassembled. Tested for operation and leaks, no more issues at this time.


Brandon B.

Brandon B. Job Checkin

Entry way lavy sink repair. Customer has tried multiple times to repair pop up assembly for entry way bathroom but keeps leaking or breaking. Pop up assembly was not assembled correctly, removed and reassembled. Tested for operation and leaks, no more issues at this time.


Brandon B.

Brandon B. Job Checkin

We will remove old equipment per EPA regulations and install a 4 Ton Trane 17 SEER Two Stage Cool with a 80% Two Stage Heat with True Variable Speed Blower. New plenums for supply and return included with duct replacement, new supply registers included. New supply added to to living room for more airflow to the area.. we are adding a return to front entryway. Run new 7/8ths line set to include a line set cover. New electrical disconnect and electrical whip. New Nest thermostat included. Raise condenser to accommodate enough clearance from house. Permits and Title 24 testing included. Per Ken Add Bradford White 50 Gallon natural gas with new expansion tank installed to be brought up to code. New water supply lines, straps. Per Ken.


Brandon B.

Brandon B. Job Checkin

We will remove old equipment per EPA regulations and install a 4 Ton Trane 17 SEER Two Stage Cool with a 80% Two Stage Heat with True Variable Speed Blower. New plenums for supply and return included with duct replacement, new supply registers included. New supply added to to living room for more airflow to the area.. we are adding a return to front entryway. Run new 7/8ths line set to include a line set cover. New electrical disconnect and electrical whip. New Nest thermostat included. Raise condenser to accommodate enough clearance from house. Permits and Title 24 testing included. Per Ken Add Bradford White 50 Gallon natural gas with new expansion tank installed to be brought up to code. New water supply lines, straps. Per Ken.


Brandon B.

Brandon B. Job Checkin

We will remove old equipment per EPA regulations and install a 4 Ton Trane 17 SEER Two Stage Cool with a 80% Two Stage Heat with True Variable Speed Blower. New plenums for supply and return included with duct replacement, new supply registers included. New supply added to to living room for more airflow to the area.. we are adding a return to front entryway. Run new 7/8ths line set to include a line set cover. New electrical disconnect and electrical whip. New Nest thermostat included. Raise condenser to accommodate enough clearance from house. Permits and Title 24 testing included. Per Ken Add Bradford White 50 Gallon natural gas with new expansion tank installed to be brought up to code. New water supply lines, straps. Per Ken.


michael E.

michael E. Job Checkin

Rocklin California, Performed heating maintenance. Visual inspection of electrical (good) no burnt or overheated wire connections, Control board shows some wear fracture cracks starting on solder joints. Same as last inspection haven’t gotten worse. blower motor capacitor test at 9.3 just below manufacturers tolerance allowed +/- .6% = 9.4, Tested amp draws (good), Flame sensor reading 2.5 (good) Burners clean, Heater safeties good, Gas pressure 3.38 just below manufactures specifications Adjusted to MFG specs of 3.5 part of heating maintenance, ohms reading of hot surface igniter 74.3 Recommend repairs replacement of capacitor to prevent problems with blower motor if capacitor was to completely fail. Possible problems that can occur control board failure due to water corrosion on control board and or fracture cracks becoming bad connections