520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Job Locations
for glenmoore, pa


Map of Glenmoore PA
Paul W.

Paul W.


Job Checkin

Installed new Daikin mini split system. Drilled hole to outside wall for lineset. Mounted backing plate and made lineset and electrical connections. Ran linehide down wall and installed cover. Ran new electrical circuit to breaker panel and wired in. Made lineset connections at outdoor unit. Pressure tested then evacuated down to 330 microns. Released charge and tested system. Everything working as it should. Relocated existing thermostat to other side of wall.