Joseph D.

Joseph D. Job Checkin

The following proposal details the recommendations discussed during the site visit at your home. The line items are generally prioritized to help best address your stated concerns and achieve your home performance goals. At the bottom of the proposal you will find the total amount of applicable PECO rebates applied by completing all of the recommendations. We look forward to helping make your home a healthier and happier place by improving comfort and efficiency while increasing value and durability. Please confirm receipt of the proposal and let us know if you have any questions and/or want to schedule any work to be completed. You can also accept the estimate to continue your home performance journey with us and start the scheduling process.


Joseph D.

Joseph D. Job Checkin

This estimate covers the recommended insulation removal and mold treatment for your attic as discussed.


Luis T.

Luis T. Job Checkin

Recently installed boiler not producing hot water or heating for the home, upon arrival found boiler on code D3, check water pressure and reading 15 psi, released some water so low water cutoff would reset, also during process noticed back side for low voltage connections, t t were not making good contact, repaired low voltage connection....check for operation ok boiler is working within specifications


Luis T.

Luis T. Job Checkin

Arrived at customers home and checked boiler for why it is not heating. Found code d3. d3 code is low water cutoff. Purged air out of system. Small air pocket trapped at LWCO. Ran system for an extended period of time and no more code. Heating home nicely. Initially automatic water feeder not feeding water automatically. Made adjustments and now is working and holding pressure at 15psi. Performed Quality Assurance inspection on a newly installed gas high efficiency boiler. Checked over entire system. Checked programming. Everything is proper and correct. Venting proper and good pitch. Checked for water leaks. No leaks present. No gas leaks. System running great when I finished. System looked really good.


Paul W.

Paul W. Job Checkin

Drained and removed old hot water heater and boiler. Installed new Bosch combi boiler. Installed new zone valves, circulator pump, air eliminator, shutoff valves, gas piping, condensate pump and vinyl, water cop main shutoff, and ran new flue piping. Installed 2 new thermostats. Filled purged and tested boiler and hot water heater. Tested combustion and pump. System working great at time of install.


Luis T.

Luis T. Job Checkin

Review and prep for upcoming boiler install