Luis T.

Luis T. Job Checkin

Maintenance Plan 2021-2022, no heat found blank thermostat, found no power to stat no 24 volts, open fuse replaced fuse and test operation cycle system con cool and heat couple times check low voltage wiring no issues were found, test furnace side performed combustion test ok no issues found on why fuse was open, sometimes is a one time or coils be intermittent problem.


Luis T.

Luis T. Job Checkin

Performed quality assurance on recently installed ac units, indoor coils with air cleaners and outdoor units, check all electrical outdoor units, indoor coils and air cleaners, ok drain system ez trap and pump ok, discharge vinyl, check all duct connections for the entire system existing furnace and new coil, air cleaner ok all connections are tape neat, test float on pumps and test ez traps ok, check outdoor units both units look very good both units and disconnect are perfectly level. Customer is very satisfied with new units. Installation passed inspection


Luis T.

Luis T. Job Checkin

Performed gas heat tune up, check electrical low and high voltage connections ok, replaced filter, cleaned flame sensor and burners, check fuel pressures and performed combustion test also check temp rise check blower motor and cap, capacitor reading just at the minimum level, we will check during ac season next year, cycle furnace ok


David B.

David B. Job Checkin

Day 1: reclaimed and removed old trane ac unit and coil. Installed a new amana coil with an external txv installed. Ran new copper lines from indoor unit to new amana ac unit. Brazed and leak checked with nitro and bubbles. Installed new ac in a new level plastic pad with crushed rocks underneath. New disconnect box and electrical wiring to unit. Installed a new switch and outlet for condensate pump to be plugged in. Installed a new condensate drain with a ez trap wired in. New condensate pump with new vinyl tubing ran over to discharge pipe. Will collect furnace paperwork after completion of day 2. Day 2: reclaimed and removed old trane ac unit and coil, installed a new amana coil on top of existing furnace and modified supply ductwork as needed. Cut in a new Aprilaire He filter and caulked all around. Installed a new ex trap wired into unit. New condensate pump with vinyl tubing ran over to discharge pipe. Ran new copper lines from indoor coil to outdoor unit. New amana ac unit is


Luis T.

Luis T. Job Checkin

New Maintenance Plan 2021-2022 performed two ac tune ups, check electrical low and high voltage connections ok, check air filter flushed drain check temps split between supply and return, found outdoor condensers running in rough condition, repair burnt connection on floor unit, both units need work, systems are from 2002 provided options for replacement customer decided to replaced both condensers with matching indoor coils.


Luis T.

Luis T. Job Checkin

No ac heat pump not running, found outdoor heat pump void of charge r22 also indoor air handler calling for ac but one element is energized 18 amps, new system is required...consultation for new system is set up for tomorrow


Luis T.

Luis T. Job Checkin

Performed ac tune check electrical low and high voltage, check filter ok, check blower motor and capacitor ok check supply and return air temperature check outdoor unit refrigerant pressures capacitor and contactor found capacitor reading below standard cycle unit ok


Luis T.

Luis T. Job Checkin

Performed ac tune up check electrical low and high ok replace filter 413 flushed drain test pump ok check split check outdoor unit refrigerant pressures capacitor and contactor ok coil is clean cycle unit ok


Luis T.

Luis T. Job Checkin

No ac, found System off at the thermostat set thermostat at air-conditioning mode 60° inside temperature is 74° check air filter OK check supply and return temperatures supply temperature it’s 64 return temperature 74 for only 10° difference check outdoor unit refrigerant pressures found system low on refrigerant r22 called John and explained problem, quoted for refrigerant and also provided price to install New condenser unit and indoor coil, customer decided to just add refrigerant for now. Added 2 lbs of refrigerant pressures 180/70 with 12 super heat and 12 sub cooling supply temp 54 return temp 74


Luis T.

Luis T. Job Checkin

Performed ac tune up check electrical low and high ok flushed drain test pump ok check blower cap and motor ok found system running with 13 split, check outdoor unit refrigerant pressures capacitor and contactor, cleaned outdoor coil, added refrigerant and dye into system customer ok repairs, after repairs recheck system pressures and temps now split is up to 19 pressures 220/100 cycle unit ok


Kurt M.

Kurt M. Job Checkin

Found 40/5 mfd capacitor tested at 37/5 mfd recommend replacement. Installed new 40/5 mfd capacitor. Also performed precision a/c tune up on amana a/c system. 20x25x1 air filter is clean. Checked all electrical conections and components. Checked temperature split at indoor unit. Tested capacitors inside and out. Blew out condensate drain. Checked refrigerant pressures and temperatures at indoor and outdoor units. A/c system is working fine at time of inspection.


Luis T.

Luis T. Job Checkin

Performed 6 month inspection on recently installed ac unit check electrical low and high voltage ok customer will replace filter, check pump flushed drain ok check supply and rerun air ok airflow set 1560 at second stage, outdoor pressures capacitor and capacitor ok super heat and sub cooling within specifications cycle unit ok


Luis T.

Luis T. Job Checkin

Performed gas heat inspection check electrical low and high voltage ok replaced air filter, cleaned flame sensor, check supply and return temperature, check blower cap, gas pressure ok combustion test cycle furnace ok, recommended adding whole house humidifier emailed proposal


Brian B.

Brian B. Job Checkin

Performed heating maintenance m replaced standard air filter, checked voltage, amperage and electrical connections, measured capacitor values. Tested electric back up heaters. Started heat pump, tested defrost cycle, calculated btu output. Checked operation and temperature rise across coil.


Barry P.

Barry P. Job Checkin

Heat tune up for 80kBTU single stage American Standard natural gas furnace. 40F temp rise. Cleaned flame sensor, verified HSI. Replaced filter. Electric motors mechanically sound. 6.47 amp draw. Verified thermostat operation. Adjusted gas pressure from 3.89 to 3.5 In. WC. Burners/heat exchanger in good condition. Combustion test good. Furnace is operating well at the time of this maintenance/tune up.