520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Local Reviews
for parkesburg, pa

Rated 5.0 out of 5 stars based on 13 customer reviews

Luis always does a great job..

Luis always does a great job, is on time and is always very helpful.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service, as usual!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service and always there when you need them!

Five years ago, I never heard of this company, my heater died on the coldest day of the year and I called everyone that I had seen advertised on TV and no one would come out. Someone gave me this name and they were here in a heartbeat. Same thing happened with my AC going out on the hottest day this year, and guess who was here in a minute. Really, when you're freezing or too hot to even think and your system has a problem, there is nothing more important than knowing someone will be here to help. That is this company!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always pleased with the service from this company!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Super.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Luis was great. Thanks for sending him

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service and pleased

Service Technician was on time, very nice, professional and completed work required. Very pleased.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Pleased with technicians work and he is a nice guy

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional as always

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service was great, on time and Luis is very helpful and professional.

Service was great, on time and Luis is very helpful and professional.👍

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for parkesburg, pa

Barry P.

Barry P. Job Checkin

Bubble Checked all joints of gas line. Including fittings at point in gas line where hard pipe is tied into trac-pipe and pilot tubing tap on vale and pressure tap fitting on valve. No apparent leaks. Boiler is operating well at the time of this service.


Luis T.

Luis T. Job Checkin

Customer propane boiler not heating, found boiler off upon arrival, thermostats are calling for heat but burners do not ignite. Check operation cleaned sensor and check incoming and manifold propane pressures, noticed incoming is 10 wc and when valve is energized It drops to 8 wc, check manifold and pilot would lit but not the burners, and manifold pressure is 7 wc. Increased manifold propane pressure to 13.5 inches wc now we have a drop when boiler start at 11.5 wc flow and 13.5 lock up, manifold pressure is set to 10 inches water column, would recommend contacting propane company to replace regulators both are probably over 20 years. When I arrived to site noticed water under boiler burners, after running boiler Here are a few drops coming down to the burners, informed customer about possible exchanger failure. Office to follow up with customer regards service plan modification


Barry P.

Barry P. Job Checkin

Heat Tune Up For 140K BTU Boiler. Cleaned burners and compartment. Checked gas pressure. Verified tstat/zoning operation. Checked expansion tank/Pressure. Combustion/ draft test :Good. Homeowner will contact us when low water volume issue is resolved to purge system . His well is drying up. Boiler Is working well at the time of maintenance. Homeowner became gas heat and AC Plan member.


Luis T.

Luis T. Job Checkin

New Maintenance Plan 2021-2022 performed gas heat tune up check electrical low and high voltage connections ok check air filter ok, cleaned flame sensor check burners and check manifold gas pressure performed combustion test check temp rise 112/67 good split, check system pressure total system static is .25 wc. Cycle furnace ok provided estimate to install whole house humidifier and air scrubber


Barry P.

Barry P. Job Checkin

Six Month Inspection for 1.5 Ton Daikin MiniSplit. Cleaned filters. Checked drain. Checked indoor voltage and amps. Verified breaker size. Checked outdoor wiring. Checked refrigerant pressures. Verified controller operation. 24F temp rise with fan at med high. Completed AC/HP tune up form. System is operating well at the time of six month inspection.


Luis T.

Luis T. Job Checkin

Performed ac tune up on rheem 2003 unit, found unit not working upon arrival, found thermostat off the wall, no low voltage power, air handler with hot water coil, found bad condensation pump switch, also thermostat needs to be replaced, unit takes 16x25x1 filter, could not check outdoor unit, outdoor unit is on top of the roof, there is no access from inside the apartment, 40 feet ladder is required, we will not be able Service this location to due to the height To get to the outdoor unit....No charge for today’s visit


Luis T.

Luis T. Job Checkin

Customer still experiencing high humidity reading, mainly on third floor, check temps and humidity reading with Psychrometer, ok thermostat is reading little higher than Psychrometer tried different thermostat and same reading as current thermostat, would recommended setting dehumidification feature turn on and set to 60% it may over cool the house to achieve humidity reading, also tried to relocate indoor sensor to master bedroom, customer will call office to see if any follow up is needed went up to attic to check ductwork termination did not see any opening, also check for other possible causes to create humidity dit not see any potential sources other than house envelope,


Luis T.

Luis T. Job Checkin

Replace all gaskets, new igniter/sensor, seals for heat exchanger, during repair noticed one screw for burner seal was missing found it bottom of the heat exchanger, informed customer that looks ok for now, if we have to replace burner/main front cover shield or burner gasket new from cover will be needed, we would tried to removed other two screws but most likely they will break, after repairs test boiler ok cycle couple times ok.


David B.

David B. Job Checkin

Reclaimed and removed old ac and coil. Installed a new amana coil on top of existing furnace. Coil is a piston. Installed a new condensate drain with and ez trap wired into system new condensate pump and vinyl tubing ran to discharge pipe. Flushed copper lines and brazed and leak checked with nitro and soapy bubbles. Installed a new amana ac unit in a new plastic leveled pad. New disconnect box and electrical wiring to unit. Cut in and fixed bathroom run that came off of supply and secured it to a joist. Tested and charged unit. 21* split.


Luis T.

Luis T. Job Checkin

Customer is experiencing high humidity levels on entire house, check humidity levels using Psychrometer, reading same percentages as sensor and thermostat, check airflow, and lowered cfm from 400 cfm to 360 cfm per ton, also activated dehumidification feature on thermostat, explained to customer that thermostat may over cooling the house to achieve desired humidity levels, check refrigerant pressures after airflow adjustments ok 320/140 with 4 degree super heat and 10 sub cooling, supply air 53 rerun air 70


Luis T.

Luis T. Job Checkin

Performed gas boiler tune up, check electrical low and high voltage connections ok cleaned flame sensor and igniter, cleaned boiler drain trap, check water pressure and temp ok test limit, check all inputs and outputs ok check flame signal 200 ok performed combustion test cycle boiler would recommend replacement of all gaskets and igniter/sensor kit


Luis T.

Luis T. Job Checkin

Performed system evacuation on current hvac system, system is from 2003 50 k 80% furnace with 3 ton ac unit, check operation and found system running at 17 delta split, outdoor unit refrigerant pressures 250/75; system is cooling at maximum level, at this point I would recommend system replacement, current system is working but very minimal outcome.


Luis T.

Luis T. Job Checkin

Replace oem condenser fan motor and blade test operation 7-19-21 installation of new condenser fan motor with new blade check operation check amp draw and voltage on motor ok 245 volts .8 amps system is cooling customer just replaced filter


Luis T.

Luis T. Job Checkin

Performed ac tune up check electrical low and high voltage ok replaced filter, flushed drain test pump ok check supply and return temperatures, cleaned condenser coil, check refrigerant pressures capacitor and contactor ok cycle unit ok would recommend replacing filter more often


Chris B.

Chris B. Job Checkin

Performed Quality Assurance on High Velocity System with Amana Outdoor AC Unit. Reviewed installation with homeowner. Corrected any issues that needed to be addressed. Completed Checklist form in system. No Follow Up needed. This Install Passed the QA Inspection. Only issue that was corrected was sealing up some air gaps in the supply ductwork.