Brian B.

Brian B. Job Checkin

Checked no cooling complaint, set thermostat to cooling, started air conditioner, checked air filter, blew out condensate trap. Checked refrigerant charge ok. Checked run capacitor. Found a failed hard start kit. Replaced start kit. Cycled air conditioner. Checked operation and temperature drop across coil.


Barry P.

Barry P. Job Checkin

No cooling 3.5 Ton Trane AC system. High head pressures high subcooling. Found noticeable leaks on ubends of indoor coil. By the time homeowner had shut windows TD was 20F. 21 superheat; 14 subcooling 239/67. Problems are caused by a combination of leaking indoor coil and failed)clogged piston. Advised homeowner to use less restrictive filter and keep windows shut.


Luis T.

Luis T. Job Checkin

This proposal is to provide a maintenance agreement for the 3 gas boilers in the basement and includes annual maintenance. It also addresses the leaking relief valve replacement, 4-9-2021 cleaned all three boilers, cleaned heat exchanger and flue pipe, boilers were super dirty, removed all debris, check electrical connections and check gas pressure, performed combustion test check water pressure and temp ok when doing a combustion test found two boiler running on high co, check chimney draft, air intake manifold gas pressure, gas pressures as set at 1.87wc could not adjust gas up to 3.5wc incoming gas pressure to building is 5 inches wc would recommend contacting peco to increase gas pressure also during visit replaced relief valve for boiler 2 middle boiler, check for leaks no leaks found, return visit required to check combustion on other two boiler, not sure if combustion Analyzer is working properly


Luis T.

Luis T. Job Checkin

Customer has three boilers commercial set up, customer has to add water once a week, check water pressure and reading 20 psi, customer has questions, I currently don’t have the answers I will have if I’ve get back to customer


Chris B.

Chris B. Job Checkin

Performed Precision Heating Tune Up on Weil McLain High Efficiency Boiler. Cleaned Heat Exchanger and Flame Ignitor assembly. Cleaned Condensation Pump and tested. Found pump was not pumping the proper amount of water out. Found the Check Valve on the Discharge had gone bad and was not opening properly. Replaced Check Valve and filled pump multiple times to test operation. Put system in operation and measured Combustion Readings. Found water pressure to be higher than normal at around 30 PSI. Removed Water from boiler to lower pressure down to around 20 PSI. Checked Expansion Tank and checked Water Feeder. Also found unit was intermittently going out into a lockout and then reset itself due to the Supply Water Temperature sensor. Found a loose connection at the wiring terminal for the supply water sensor. Reconnected wiring and tested. The gaskets are starting to become worn on the system. Would recommend on next tune up having all of the Gaskets replaced using the Weil McLain mainte


Brian B.

Brian B. Job Checkin

Checked no heat complaint, found thermostat blank, it’s a 2 wire thermostat, checked batteries ok. Found corrosion on the thermostat battery contacts. Cleaned thermostat contacts. Installed batteries. Checked voltage ok now. Installed thermostat. Cycled boiler and checked operation.


Brian B.

Brian B. Job Checkin

Performed heating maintenance on gas boiler, cleaned burner and ignitor. Blew out condensate trap. Checked for errors. Checked voltage, amperage and electrical connections. Started boiler, tested limit and safety switches. Measured fuel pressures. Performed combustion test. Checked boiler pressures and temperature.


Dan S.

Dan S. Job Checkin

Here in Spring City checking the refrigerant charge as part of an AC Tune-Up on a Bryant system. The Condenser is sitting on the roof with the furnace in a closet below it.

Here in Spring City checking the refrigerant charge as part of an AC Tune-Up on a Bryant system. The Condenser is sitting on the roof with the furnace in a closet below it.

Bryan D.

Bryan D. Job Checkin

Performing a Heat Tune Up on a Carrier 80% Gas Furnace in Kennett Square.

Performing a Heat Tune Up on a Carrier 80% Gas Furnace in Kennett Square.

Bryan D.

Bryan D. Job Checkin

Performing a Heat Tune Up on a Carrier 80% Gas Furnace in Kennett Square.

Performing a Heat Tune Up on a Carrier 80% Gas Furnace in Kennett Square.

Bryan D.

Bryan D. Job Checkin

Performing a Heat Tune Up on a Bryant Natural Gas Furnace.

Performing a Heat Tune Up on a Bryant Natural Gas Furnace.

Bryan D.

Bryan D. Job Checkin

Performing a Heat Tune Up on a Bryant Natural Gas Furnace.

Performing a Heat Tune Up on a Bryant Natural Gas Furnace.