Completed plan member heat tune up for 120,000 BTU natural gas furnace 20x25x1 filter ok Inspected burners, heat exchanger, ignitor, inducer assembly, pressure switches and components Indoor coil is rusty, rust marks on surface of primary heat exchanger Cleaned flame sensor with 0000 steel wool and verified flame rectification circuit Inspected wiring, controls, electric motors and components; left email estimates for surge protection devices. Confirmed proper manifold gas pressures Confirmed inducer vacuum in low and high fire operation Measured temperature rise (68°-118= 50°F) and static pressure Inspected all components of drain. There is no water safety device. Left email estimate for wet switch. Combustion, smoke and draft tests: Pass Discussed and left email estimate for APCOX whole home air purification system. Homeowner paid for Gas Heat+AC plan membership today. Furnace is operating well at the time of this tune up.


Barry P.

Barry P. Job Checkin

2 plan member Heat Tune Ups 1. 50KBTU Natural gas Comfortmaker furnace that serves basement and first floor. Replaced 16x20x1 filter. Made call for heat from thermostat. Measured hot surface ignitor resistance. Cleaned flame sensor; verified flame rectification circuit. Checked pressure switch and components. Measured temperature rise and static pressure. Checked all wiring and motors. Found weak blower capacitor. Homeowner agreed to replace. Inspection of burners ignitor and flame sensor: Good Combustion/draft test: Good Furnace is operating well at the time of this maintenance. 2. 2 Ton Comfortmaker Heat Pump with 8KW strip heater that serves 2nd floor. Replaced both 20x20x1 filters. Checked back up heat/measured amp draw of strip heater. Measured temperature rise. Checked all wiring, electric motors and components. Checked refrigerant pressures. I noted to homeowner a slight buzzing from compressor. Heat Pump system is operating well at the time of this maintenance Both sys


Barry P.

Barry P. Job Checkin

Heat tune up for 120KBTU natural gas furnace: Replaced filter. Made call for heat from thermostat/verified thermostat operation. Visual inspection of burners and heat exchanger. Checked hot surface ignitor ohms and looked for cracks/hot spots during start up. Cleaned flame sensor. Hacked flame sense/rectification circuit. Checked all electric motors and components. Checked temperature rise and static pressure. Checked gas pressure. Combustion draft test: Good Furnace is operating well at the time of this maintenance.


Luis T.

Luis T. Job Checkin

Repiped section of exhaust. Verified that entire length of exhaust was properly pitched.


Barry P.

Barry P. Job Checkin

Gas Furnace Tune Up for 80K BTU 2 stage propane furnace. Checked burners and heat exchanger. Measure temp rise. Measured inlet and outlet gas pressure. Filter ok. Checked all electric motors and components. Checked all field and manufacturer wiring. Combustion test good. Completed Gas Furnace Inspection Form We will schedule to come out and adjust exhaust. Furnace is operating well at the time of six month inspection.


Chris B.

Chris B. Job Checkin

Performed Quality Assurance on Amana Gas Furnace/AC system. Completed checklist form in system. Reviewed installation with homeowner. When we return for Six Month Heating Inspection need to adjust the straps on the Exhaust Pipe to pitch correctly.


Barry P.

Barry P. Job Checkin

Found double pole breaker outdoor breaker tripped. Reset. Found blown terminal on compressor. Will contact Jeff with estimate for compressor replacement.


Barry P.

Barry P. Job Checkin

Found failed condenser fan motor for attic Heat pump. Customer signed estimate to replace motor and fan assembly and become a plan member for both systems in the home. Replace condenser fan motor and blade assembly. 2 GAHP plan memberships.


Barry P.

Barry P. Job Checkin

AC Tune Up for 2.5 Ton Luxaire AC system. 19F temp split. Filter ok. Blew out drain; ok. Tstat operation/cycling of cooling ok. Outdoor voltage/indoor amps/compressor amps ok. All electric motors and components ok. Both coils are in good condition. System is operating well at the time of this tune up. .


Barry P.

Barry P. Job Checkin

AC Tune up for 2.5 Ton ICP AC system.19.5 temp split. Replaced filter. Drain ok. Both coils are in good condition. All electric motors and components ok. Refrigerant pressures/subcooling/superheat ok. Outdoor voltage/indoor amps/compressor amps ok. System is operating well at the time of this maintenance.


Barry P.

Barry P. Job Checkin

AC and Gas Furnace precision tune up. Cleaned tubing of exhaust fitting. Cleaned drain at secondary. Filter. Indoor amps ok. Combustion test good (97% eff.) Temp rise 50F. Filter ok. Explained humidifier operation/settings to Mrs. C. Furnace is operating well at the time of this tune up. Cooling: 15F temperature split. Cleaned evaporator drain/ verified condensate pump operation. Both coils are in good condition. Outdoor voltage/compressor amps/ capacitor ok. Refrigerant pressures/superheat/subcooling ok. System is operating well at the time of this tune up.


Luis T.

Luis T. Job Checkin

Installed t10 smart thermostat with room sensor, and service plan. Heat tune up for 80K BTU single stage Luxaire propane furnace. Cleaned flame sensor. HSI Ohms 45; ok. Adjusted gas pressure from 8.89” WC to 10”WC. Temp rise Heat Pump 16F; temp rise furnace 53. All electric motors and components ok. Combustion test ok. Furnace is working well at the time of this maintenance/tune up.


Barry P.

Barry P. Job Checkin

Heat tune up on single stage gas furnace. Changed filter; cleaned flame sensor. Hot surface ignitor ok. Electrical components ok. Gas pressure and flame ok; burners in decent condition at this time. 70F temp rise. Cleaned secondary drain. Verified operation of both thermostats. Combustion test proves integrity of heat exchanger. Furnace is operating well at the time of this maintenance/tune up.


Luis T.

Luis T. Job Checkin

Customer complain is that bedroom is hotter and colder than other parts of the house, check airflow and temp coming out of vent,,good volume come out at 50 degree, room is 13x14, ductwork is not exposed, booster fan would not help in this situation, could be noise and will be uncomfortable, would recommend setting fan to ON all the time This will could bring more comfort inside the room would even out the temp from rest of the house, is this seems to help new thermostat with room sensor should be installed could be installed, this would take the average of the room and rest of the house, customer wants to installed t10 with sensor and also performed heat tune up,


Luis T.

Luis T. Job Checkin

No heat found unit off on pressure switch code, reset unit and test operation unit would run for minute or two then shuts off on pressure switch, check vacuum and venting ok, inducer had some water, exhaust drain port had some blockage, cleared drain port behind inducer and check in line vacuum negative pressure and is over rated pressure switch, one side is -.70 and condensate port is -1.45 one switch is rated at -.35 and other is rated at -.75 wc. After cycling furnace couple times run heater for 20 mins and performed combustion test, noticed intake and exhaust termination is under a deck informed customer and recommended extending intake all the way to the outside of deck