Cody C.

Cody C. Job Checkin

DCM1 service 1 of 2 AC completed changed (1) 16x25x1 filter, tested system operation’s everything is operating properly at this time attached isn AC maintenance checklist.


Cody C.

Cody C. Job Checkin

DCM6: Heat complete, Replaced (4) 20x20x1 and washed other filters. All systems are fully functional and are operating within manufacturer specifications at this time. Heat maintenance checklist attached.


Cody C.

Cody C. Job Checkin

DCM1 service 1 of 2 Heat completed changed (1) 16x20x1 filter, tested system operation’s everything is operating properly at this time attached is Heat maintenance checklist.


Rob  S.

Rob S. Job Checkin

DCM1 complete; AC; (1) F16201 replaced. System is fully functional. All components are operating within manufacturer specifications. Refrigerant pressures and temperatures are appropriate for indoor and outdoor conditions. AC checklist and diagnostics photos attached


Cody C.

Cody C. Job Checkin

DCM2 service 1 of 2 Heat completed changed (2) 16x25x1 filters tested system operation’s everything is operating properly at this time attached is Heat maintenance checklist.


Brad  N.

Brad N. Job Checkin

DCM1 :Service 2 of 2 Heat Changed (1)16x25x1, Performed Heating Maintenance Per Checklist System is running at this time. Homeowner is living in home it is no longer a rental property.


Cody C.

Cody C. Job Checkin

DCM1 service 1 of 2 Heat completed changed (1) 20x20x1 filter, tested system operation’s everything is operating properly at this time attached is Heat maintenance checklist.


Cody C.

Cody C. Job Checkin

Reversing valve was not switching over into heat mode. Found loose B wire on outdoor HP from install. Re-wired HP is operating properly.


Cody C.

Cody C. Job Checkin

Removed old electric meter monitor wire.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Removed old equipment and installed new rheem 2 ton 2 stage heat pump and air handler. Removed old support shelf and built new support shelf for air handler to sit on. Installed new external filter rack with 16x20x1 filter, new coil safety switch, new nest thermostat and new composite pad for outdoor unit. Reconnected supply plenum, high voltage, low voltage, drain line and lineset. Tested system operations, set proper charge.


Rob  S.

Rob S. Job Checkin

DCM1 complete; AC; (1) F16254 replaced. System is fully functional. All components are operating within manufacturers specifications. Refrigerant pressures and temperatures are appropriate for indoor and outdoor conditions. AC checklist attached


Cody C.

Cody C. Job Checkin

Added (2) pounds of R22 to hold over until install dates. Windows are not applicable for a portable unit.


Cody C.

Cody C. Job Checkin

DCM1 service 2 of 2 AC completed, switched over reversing valve to make sure heat does run, changed (1) 16x20x1 filter, tested system operation’s everything is operating properly at this time attached is AC maintenance checklist.


Brad  N.

Brad N. Job Checkin

Call for system not keeping up. On arrival system was off. I turned on to check operation and the system did energize. I checked the filter and blower wheel and found the blower wheel completely dirty, clogged and negatively impacting air flow and system performance. I pulled the blower out to see evaporator coil and it is also very dirty. would need to start with the blower cleaning and evaporator coil to get a accurate refrigerant readings, this is a 2 technician job, due to the age, condition, efficiency, amount of cleanings and the fact that R22 started phase out January 1, 2020.


Brad  N.

Brad N. Job Checkin

Call for system freezing up, on arrival system was running, checked pressures, psi 47/176, SH49, SC5, system is low on charge 1 to 3lbs of R22, blower is dirty and covered in micro biological growth that is negatively affecting system performance, Evaporator Coil is leaking, rusted and deteriorating, system is in overall poor condition and it is recommended to consider replacing and upgrading system due to age, condition, efficiency, and the fact the system is leaking R22 refrigerant that has been phased out as of January 1, 2020. Pictures Attached.