4720 Industrial Access Rd.
Douglasville, GA 30134
770-445-8923

Local Reviews
for canton, ga

Rated 5.0 out of 5 stars based on 5 customer reviews

Humidifier

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Amazing Service, as Always!

Alex came out and completely overhauled our system. He resolved a number of issues caused by the horrible company that originally installed system.

  • Overall Experience
  • Quality
  • Price
  • Convenience

friendly service tech and value priced

first time using Dobb's , was very pleased - Khalil called right on time and arrrived as scheduled

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for canton, ga

Dobbs Technician A.

Dobbs Technician A. Job Checkin

Today I arrived to service Mr Moore units. Everything was operating under manufacture specifications.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Completed 2 system cooling maintenance, replaced filters, both units operating properly at this time. Estimate and pictures included


Dobbs Technician A.

Dobbs Technician A. Job Checkin

DCM2: Heat complete, replaced 14x20x1, 16x20x1 and 20x20x1 filters provided by homeowner. Both systems are fully functional and operating within manufacturer specifications at this time. Homeowner mentioned back room over garage is cooler in the winter and warmer in the summer. Talked to homeowner about adding duct work to the room if possible or installing a mini split in his garage. He wanted to speak with his wife about having a comfort advisor out, told him the shop would call Monday morning to schedule. Maintenance checklist attached.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

DCM1: Heat completed. Changed 16x25x1 filter System is fully functional and operating within manufacturer specifications at this time. Heat rise of 60 degrees. No issues found.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Checked systems 1-7 and 9-10. System 1- arrived to main breaker tripped, reset breaker and checked operations. System has a 35amp 2 pole breaker the system says the minimum breaker size should be 36amp and maximum being 60amp. Wire to breaker is also undersized. It’s 9 gauge wire and needs to be 6 gauge to properly transfer voltage. Drain line was also broken, repaired drain line and added a clean out, deep trap, vent and insulation to help with drainage. Photos attached. System 2- quoted recently. System 3- quoted recently. System 4- is functional and operating within manufacturer specifications at this time, refrigerant pressures and temperatures are appropriate for indoor and outdoor weather conditions. System 5- system is not moving enough air for the system to work properly. Tried to adjust settings and blower speeds but there is no way to do so on this air handler. Will need to increase the size of the air handler for system to function properly. System 6- is fully funct


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Replaced April’s wire 35 water panel


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Performed single system heat maintenance, furnace operating properly at this time. Mr.said he will replace 16x25x4 filter


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Performed 2 System Heat maintenance, both operating properly.


Rob  S.

Rob S. Job Checkin

Arrived to system over cooling Check temperatures in Dining Room, Bed room, Kitchen/Living room. With system off all rooms reporting same temperature as thermostat, thermostat reporting accurate temperature in the conditioned space 75 Degrees. With system running rooms cool quicker than the thermostat is reporting. Bedroom 3 degrees cooler than temperature at thermostat. Dining room 2 degrees cooler than temperatures at thermostat. Kitchen/ Living room 2 degrees cooler than temperature at thermostat. Thermostat 1.5. Caulk thermostat wire penetration in the wall and recalibrated thermostat temperature. Manually offset temperature -2 degrees.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Did spm2 on both units, replaced 20mfd run capacitor on downstairs indoor blower, units operating properly


Dobbs Technician A.

Dobbs Technician A. Job Checkin

DCM1: A/C complete, replaced 16x25x1 filter. System is fully functional and operating within manufacturer specifications at this time. Refrigerant pressures and temperatures are appropriate for outdoor and indoor weather conditions. Temp split 18. No SS2 water safety however does have a pan safety.


Keith D.

Keith D. Job Checkin

Quote new furnace and air conditioner


Cody C.

Cody C. Job Checkin

DCM1 service 1 of 2 AC completed changed (1) 16x25x1 filter, tested system operations everything is operating properly at this time attached is Zac maintenance checklist.


Cody C.

Cody C. Job Checkin

DCM2; Heat completed, replaced (1) F14x20x1, (1) F20x20x1, (1) F16x20x1, both units are operating within manufacturer design at this time. Attached is Heat maintenance checklist.


Cody C.

Cody C. Job Checkin

Upon arrival investigated heat strip contactor, pulling in and out, was losing 24V call at contactor, low voltage in unit, discovered a rats nest as culprit, re-wired, stripped back low voltage wires to ensure all contacts were making proper connections. Was not able to replicate issue afterwards. Belt on unit is extremely worn and tattered, need to replace to prevent any airflow issues, will need a A47. Heat strip sequencer in arching, would strongly recommend replacing heat strip to prevent from burning up.