DCM1 :Service 1 of 2;AC, Changed 16x25x4, Performed Cooling Maintenance Per Checklist System is running at this time.
Install Trane Thermostat under part warranty, tested thermostat is working at this time.
DCM1 :Service 2 of 2 ;AC Changed 12x25x1 filter, Performed Cooling Maintenance Per Checklist, system is running at this time but due to age multiple part failure is possible at any time.
DCM1 :Service 2 of 2 ;Heat, Changed (1) 20x20x1, Performed Cooling Maintenance Per Checklist, system is running at this time but due to age and condition multiple part failure is possible at anytime.
DCM1 service 1 of 2 Heat: Changed (1) 20x20x1 filter, Performed Heating Maintenance Per Checklist, System is running at this time.
DCM2 :Service 1 of 2, A/C, Changed 1) 20x25x5, (1) 16x20x1, Performed Cooling Maintenance Per Checklist, Systems are running at this time.
Call for no heat, on arrival system was giving same error codes as previous visit, still had the Nexia 850 thermostat on the van and decided to install it to help try and rule out a bad thermostat, system did start heating at this time.
No Heat call thermostat was showing multiple indoor and outdoor units had to go and do a factory reset inside installer setup, problem fixed and checked operation system is running at this time.
DCM2 service 2 of 2 Heat completed checked (2) 16x20x4 changed (1) 16x20x1 filters, tested system operation’s everything is operating properly at this time attached is heat maintenance checklist.
DCM1 service 1 of 2 Heat completed changed (1) 16x20x1 filter, tested system operation’s everything is operating properly at this time, peered went out at home was unable to check charge on system. Attached is heat maintenance checklist.
DCM1 :Service 2 of 2 ;Heat, Changed (1) 22x22x1, Performed Heating Maintenance Per Checklist, system appears to be running normally at this time. Homeowner has been having a intermittent issue during heating that the temperature drops they are going to keep a close watch on it, it is believed that the heat strips may not be energizing when going into defrost mode.
Quoted new high efficiency heat pump system
Upon arrival no heat blower motor was not operating, capacitor was reading 0MFD and is a 10MFD. replaced capacitor with homeowners approval, fan started up as intended, system is operating properly at this time, system is 20 years old homeowner would like quoted for replacement confirmed Tuesday the 7th in the 4-5 for comfort specialist.
DCM1 service 2 of 2 heat completed changed (1) 16x25x4 filter, tested operation everything is operating properly at this time attached is Heat maintenance checklist.
DCM1 :Service 1 of 2 ;AC, Changed (1) 20x20x1, Performed Heating Maintenance Per Checklist, System is running at this time but due to age and condition multiple part failure is possible at anytime. Due to ages and condition it is recommended to start considering to replace and upgrading system for better performance, reliability, efficiency, and peace of mind.