Shawn did an excellent job. He was on time, efficient and thorough.
Response from Edison Heating & Cooling:
We count ourselves lucky for customers like you and look forward to working with you again in the future!
Response from Edison Heating & Cooling:
We are pleased to know your experience with us was a good one!
It was a pleasure having Shawn handle my maintenance on my unit. He was very knowledgeable, detailed, efficient and personable. It was great to see a young man handle himself in such a respectable manner. I was truly impressed with his visit. We need more examples like him. Keep up the great work Shawn. Best wishes in all your endeavors.
Response from Edison Heating & Cooling:
It was a pleasure serving you and your family. We really appreciate you taking the time to share your feedback with us and the community.
Sean came on time, did a thorough job, was courteous, and efficient.
Response from Edison Heating & Cooling:
It was a pleasure serving you and your family. We really appreciate you taking the time to share your feedback with us and the community.
Evan was professional, friendly and knowledgeable. I will request him next year for my A/C unit maintenance.
Excellent, personable and knowledgeable technician. Great experience that ensures customer satisfaction and confidence.
Chris was great! He recommended what we needed to maintain this expensive Carrier HVAC system!
Adrien was the perfect technician and explained everything he was doing.
JaQuan called ahead, arrived when he said he would and was very efficient and professional the whole time. He did excellent work and provided details of everything that was performed, tested and replaced. Thank you.
He did a great job
Performed routine maintenance on the boiler and generator. For the boiler, I checked and cleaned the burner assembly, inspected the heat exchanger for any signs of wear, and tested the pressure relief valve for proper operation. I also checked the water level and refilled as needed. For the generator, I inspected the fuel system, changed the oil, replaced the air filter, and tested the battery. Both systems were thoroughly checked and are now operating efficiently, ensuring reliable performance for the upcoming season.
Performed routine maintenance on the furnace. Inspected and cleaned the burner assembly, checked the heat exchanger for any cracks, and tested the thermostat for accurate readings. Replaced the air filter and lubricated the blower motor. Confirmed that the system was functioning efficiently and safely, ensuring reliable operation throughout the heating season.
I installed an air scrubber to improve the indoor air quality in a residential home. After mounting it in the HVAC ductwork, I connected it to the system's power supply. I tested the UV light and ionizer to ensure they were operating correctly, effectively reducing airborne contaminants like dust and pollen. The system is now working efficiently to improve the home's air quality.
Performed furnace maintenance, including a thorough cleaning of the heat exchanger and blower assembly. Inspected and replaced the air filter, checked the thermocouple, and ensured the ignition system was functioning properly. Tested the system’s safety controls and calibrated the thermostat for accurate temperature regulation. The furnace is now ready for efficient operation throughout the heating season.
Performed routine AC maintenance on a Carrier Performance 16 unit. Began by cleaning the condenser coils to remove any dirt and debris that could impede airflow. Checked the refrigerant levels and adjusted them to the manufacturer's specifications. Inspected the electrical connections and tightened any loose wires. Lubricated the fan motor and ensured the thermostat was calibrated correctly. After completing the maintenance, tested the system to confirm efficient operation and optimal cooling performance. The unit is now running smoothly.
Performed comprehensive AC maintenance on a residential unit. Checked refrigerant levels using a manifold gauge and added R-410A as needed. Cleaned condenser and evaporator coils with a foaming coil cleaner for optimal heat transfer. Inspected and tightened all electrical connections. Lubricated motor and blower bearings. Cleared the condensate drain to prevent water buildup. Replaced the air filter and calibrated the thermostat for accurate temperature control. Tested the system to ensure efficient and reliable operation.
Performed maintenance on an HVAC system reported for no cooling. Inspected the unit and found a dirty air filter and clogged condenser coils, both restricting airflow. Replaced the air filter and thoroughly cleaned the condenser coils. Checked the refrigerant levels and added R-410A to reach optimal pressure. Examined the electrical components, including capacitors and contactors, for proper operation. After completing these tasks, tested the system to ensure it was cooling efficiently.
Responded to a no cooling call on a Goodman GSX160361 air conditioner. Checked capacitor with a meter and found the dual run capacitor shorted. Replaced faulty 35/5 MFD capacitor with new Titan Pro replacement. Verified proper operation of compressor and condenser fan motor after new capacitor install. Performed unit cooling cycle test, measuring 22°F superheat and 10°F subcooling within expected parameters. Recommended customer schedule annual preventative maintenance to help extend equipment life. Provided quote for capacitor and labor.