Installed APCO-X Dual UV-C Air Purifier in Succasunna, NJ residence. Mounted unit in supply plenum of existing Carrier 59TP6A furnace. Utilized 24V power from control board, ensuring interlock with blower operation. Positioned dual UV-C lamps for maximum exposure to airstream. Installed carbon matrix cells for VOC reduction. Programmed LED indicator for lamp life monitoring. Measured airflow impact: negligible at 0.07" w.c. Performed post-installation air quality test, noting 97% reduction in microbial contaminants and 85% decrease in VOCs.
In Succasunna, NJ working on HVAC repair today. Diagnosed issue as a faulty compressor capacitor, causing compressor failure. Used a multimeter to measure capacitance and confirmed low readings. Replaced capacitor with a new one matching manufacturer specifications. Inspected electrical connections for tightness and corrosion, ensuring safe operation. Cleaned condenser coils to optimize heat transfer. Tested system operation and monitored refrigerant pressures and temperatures to confirm proper function. Conducted final inspection and ensured system integrity. Provided recommendations for preventive maintenance to enhance system longevity and efficiency.
Installing an air handler and condenser with Anthony and AJ
Performed annual preventative cooling maintenance.