Completed a spring diagnostic and repair on a Lennox XC25 system. The unit was short-cycling due to a faulty run capacitor and low refrigerant levels. Replaced the capacitor and recharged the system with R-410A. Verified stable operation and proper airflow.
Performed seasonal maintenance on a Carrier Infinity 24VNA9. Cleaned condenser coils, checked thermostat calibration, tested refrigerant charge, and inspected blower motor amperage. System is operating at optimal cooling efficiency for spring.
Responded to a no-cool call on a Trane XR16 system. Found a failed contactor and signs of arcing at the disconnect. Replaced contactor and verified voltage at the terminal strip. AC is now running reliably.
Conducted a comprehensive AC tune-up on a Bryant Evolution 189BNV. Cleaned evaporator coil, flushed the condensate line, tested compressor amps, and measured delta T across the coil. Unit is performing within manufacturer specs.
Completed preventive maintenance on a Goodman GSXC18 system. Checked refrigerant charge, inspected capacitor (45/5 mfd), and cleaned debris from condenser fins. System is ready for increased spring usage.
Serviced a York YXV 20 SEER system. Corrected a refrigerant leak at the service valve using a flare nut torque wrench and sealed with approved leak sealant. Verified pressures and system operation post-repair.
Performed a spring tune-up on an American Standard Gold 17 unit. Inspected blower motor bearings, cleaned condenser coil with non-acid cleaner, and verified airflow at 425 CFM per ton. All components functioning well.
Troubleshot a Lennox SL28XCV with poor cooling performance. Detected a weak dual run capacitor (rated 60/7.5 mfd, tested at 49/6). Replaced with OEM part and rechecked microfarad ratings under load.
Replaced an outdated heat pump for a homeowner in Pleasant Hill, CA, upgrading to a high-efficiency model. The old system struggled with frequent breakdowns and high energy bills. Installed the new unit, optimized the refrigerant charge, and tested the system for proper heating and cooling performance. Calibrated the thermostat and ensured seamless integration with existing ductwork. The new heat pump delivers reliable comfort, improved efficiency, and lower operating costs year-round.
Completed a furnace replacement for a homeowner in Pleasant Hill, CA. The old unit had a cracked heat exchanger, posing a safety risk. Installed a high-efficiency gas furnace, ensuring improved performance and energy savings. Connected and tested all components, including the thermostat, ductwork, and safety controls, for optimal functionality. Checked airflow and gas pressure to ensure smooth operation. The new furnace provides reliable heating, enhanced comfort, and reduced utility costs. The homeowner is now ready for the colder months with peace of mind!
Addressed an issue with a Trane XR15 air conditioner that was not cooling and making a clicking noise. Diagnosed the problem as a faulty contactor and low refrigerant levels. Replaced the malfunctioning contactor to resolve the clicking noise. Located and repaired a refrigerant leak in the evaporator coil, then recharged the system with R-410A refrigerant. Checked system pressures and tested for optimal superheat and subcooling values. Ensured the unit is now cooling effectively and operating quietly.
Fall furnace service and heating maintenance check-up. This essential service will help the homeowner's unit work better all winter long with a much less chance of any breakdowns. It also will save the client money on energy costs and will keep the home more comfortable.
Furnace maintenance on a RUUD unit.
Installed a new American Pride Ac system.