Arrived on site to perform B2 fall tuneup. Found rust and oxidation on bottom of heat exchanger plates and intermittently throughout chamber. Found two holes while running inspection camera. Pulled blower and verified two cracks with separation. Furnace is unsafe to run with compromised heat exchanger. Furnace is 18 years old and outside of average lifespan. Blower motor has substantial buildup and has oil residue on casing. Turned off gas cock and advised not to operate until heat exchanger is replaced or new Furnace installed