850 U.S. 9
Fishkill, NY 12524
845-896-4328

Job Locations
for carmel hamlet, ny


Map of Carmel Hamlet NY
Scott Y.

Scott Y.


Job Checkin

C/S Gas. Upon arrival found humidifier leaking from bottom of humidifier, found when we replaced pad last spring for customer we did not have bracket holding pad fully secured inside of humidifier, secured pad in correct position allowing the drain hole to align with the drain hose. Tested inducer, gas valve, flame sensor, igniter, pressure switch, blower motor and capacitor. Customer has uv light, electronic filter, and humidifer. Customer had replacement pads, and filters, replaced both humidifer pad and filter. Performed combustion test. Found blower capacitor reading under manufacturer rating, recommend to replace. Could not get a hold of husband regarding capacitor, he was at a meeting for work and wife had to leave house so I could not stay at location. Sent estimate for capacitor to customers email. System is running normally.