Job Locations
for croton-on-hudson, ny

Folkes H.

Folkes H. Job Checkin

Connect the unit back onto the wall in the same spot. Pressure test and evacuate the entire system. 4 indoor units and 1 outdoor unit. Then recharge the system with 11lbs of refrigerant. 11/16/21 Re-installed wall mounted indoor unit in front bedroom. Re-connected lineset, wiring and drain pipe. Pressure tested, evacuated and charged system. Started all units.


Chris H.

Chris H. Job Checkin

Customer had no heat in home, her relief valve had popped so unit was turned off, found expansion tank had failed and filled with water, also relief valve no good, as well as the air vent clogged, also shut off valve for top floor broken so no way to purge top floor, sweat in new ball valve, replaced expansion tank, air vent, relief valve and purged system, let boiler run through two cycles, and felt radiators. All supply and returns got hot. System operational and working.


Chris H.

Chris H. Job Checkin

Unit not getting any power from thermostat, customer had insulation separated in attic from her contractor and found emergency float switch pinched under insulation, resecured float switch to emergency pan and unit came right on, no error codes at air handler or thermostat, let system run for 20 minutes and took delta t reading which was at 30 degrees, also changed return filter that was plugged from construction in home 14x14x1. Customer was not home only contractor will need to bill customer.


Noah  D.

Noah D. Job Checkin

Recover the refrigerant from the system and take the 1 indoor unit off the wall until the demolition is done. After removing the one system tested operation of the other 3 units.


Noah  D.

Noah D. Job Checkin

The customer would like one indoor unit on a room removed off the wall for a period of time while the demolition gets done and finished then would like it placed back on the wall. The only issue with this is you can not isolate that one unit with the branch box that is installed. We would need to recover all the refrigerant out of the system then remove the unit but the other 3 units will not work. Gave the estimates to the home owners for the work. She will call us when she is ready to get the work done.


Folkes H.

Folkes H. Job Checkin

Installed 2.5 ton 16 seer Amana heat pump condenser. With 2.5 ton Amana air handler with ECM blower. Drain pan with float switch, merv 11 air filter, condensate trap and drain plumbing. New ac pad and block. New line cover, lineset. All new low and line voltage wiring. All new ductwork, 10 supplies and 1 central return with 16” flex and 30x20 grill. Installed customer provided nest thermostat. Started and tested.